Quantification of plasma-derived blood coagulation factor VIII by real-time biosensor measurements


Pflegerl, Karin; Hahn, Rainer; Schallaun, Eva; Josic, Djuro; Jungbauer, Alois
Quantification of plasma-derived blood coagulation factor VIII by real-time biosensor measurements // Journal of Chromatography B: Biomedical Sciences and Applications, 752 (2001), 2; 335-347 doi:10.1016/s0378-4347(00)00515-6 (međunarodna recenzija, članak, ostalo)


CROSBI ID: 990398 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Quantification of plasma-derived blood coagulation factor VIII by real-time biosensor measurements

Autori
Pflegerl, Karin ; Hahn, Rainer ; Schallaun, Eva ; Josic, Djuro ; Jungbauer, Alois

Izvornik
Journal of Chromatography B: Biomedical Sciences and Applications (0378-4347) 752 (2001), 2; 335-347

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, ostalo

Ključne riječi
Real-time biosensor ; Factor VIII ; Monoclonal antibody

Sažetak
Plasma-derived blood coagulation factor VIII was analyzed in real time using biosensor technology. Monoclonal antibodies directed against the heavy and against the light chain of factor VIII were immobilized on different carboxymethyl dextran surfaces. Different factor VIII concentrations were injected over the antibody surfaces in parallel and response levels were determined from the dissociation phase at a fixed time after sample injection. Serial dilutions of plasma-derived factor VIII with known concentrations determined by a commercial FVIIIC:Ag ELISA were used as standards. A quantification limit of 0.9 I.U./ml with antibody 530p and 1.5 I.U./ml with antibody 531p was calculated. Intra-assay precision expressed as percent coefficient of variation was below 10% for concentrations above 0.6 I.U./ml. Inter-assay precision for antibody 530p was below 20% for concentrations higher than 0.6 I.U./ml. For 531p, inter-assay precision was below 10% for concentrations higher than 2 I.U./ml. A sensor chip lifetime in respect to regeneration of at least 100 cycles for both antibodies was found. The small sample requirement of 35 μl allows fast analysis of different FVIII products and the use of two monoclonal antibodies directed against two different FVIII domains provides additional information about the integrity of the FVIII molecule.

Izvorni jezik
Engleski

Znanstvena područja
Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)



POVEZANOST RADA


Ustanove:
Sveučilište u Rijeci - Odjel za biotehnologiju

Profili:

Avatar Url Đuro Josić (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Pflegerl, Karin; Hahn, Rainer; Schallaun, Eva; Josic, Djuro; Jungbauer, Alois
Quantification of plasma-derived blood coagulation factor VIII by real-time biosensor measurements // Journal of Chromatography B: Biomedical Sciences and Applications, 752 (2001), 2; 335-347 doi:10.1016/s0378-4347(00)00515-6 (međunarodna recenzija, članak, ostalo)
Pflegerl, K., Hahn, R., Schallaun, E., Josic, D. & Jungbauer, A. (2001) Quantification of plasma-derived blood coagulation factor VIII by real-time biosensor measurements. Journal of Chromatography B: Biomedical Sciences and Applications, 752 (2), 335-347 doi:10.1016/s0378-4347(00)00515-6.
@article{article, author = {Pflegerl, Karin and Hahn, Rainer and Schallaun, Eva and Josic, Djuro and Jungbauer, Alois}, year = {2001}, pages = {335-347}, DOI = {10.1016/s0378-4347(00)00515-6}, keywords = {Real-time biosensor, Factor VIII, Monoclonal antibody}, journal = {Journal of Chromatography B: Biomedical Sciences and Applications}, doi = {10.1016/s0378-4347(00)00515-6}, volume = {752}, number = {2}, issn = {0378-4347}, title = {Quantification of plasma-derived blood coagulation factor VIII by real-time biosensor measurements}, keyword = {Real-time biosensor, Factor VIII, Monoclonal antibody} }
@article{article, author = {Pflegerl, Karin and Hahn, Rainer and Schallaun, Eva and Josic, Djuro and Jungbauer, Alois}, year = {2001}, pages = {335-347}, DOI = {10.1016/s0378-4347(00)00515-6}, keywords = {Real-time biosensor, Factor VIII, Monoclonal antibody}, journal = {Journal of Chromatography B: Biomedical Sciences and Applications}, doi = {10.1016/s0378-4347(00)00515-6}, volume = {752}, number = {2}, issn = {0378-4347}, title = {Quantification of plasma-derived blood coagulation factor VIII by real-time biosensor measurements}, keyword = {Real-time biosensor, Factor VIII, Monoclonal antibody} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font