Pregled bibliografske jedinice broj: 990398
Quantification of plasma-derived blood coagulation factor VIII by real-time biosensor measurements
Quantification of plasma-derived blood coagulation factor VIII by real-time biosensor measurements // Journal of Chromatography B: Biomedical Sciences and Applications, 752 (2001), 2; 335-347 doi:10.1016/s0378-4347(00)00515-6 (međunarodna recenzija, članak, ostalo)
CROSBI ID: 990398 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Quantification of plasma-derived blood coagulation factor VIII by real-time biosensor measurements
Autori
Pflegerl, Karin ; Hahn, Rainer ; Schallaun, Eva ; Josic, Djuro ; Jungbauer, Alois
Izvornik
Journal of Chromatography B: Biomedical Sciences and Applications (0378-4347) 752
(2001), 2;
335-347
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, ostalo
Ključne riječi
Real-time biosensor ; Factor VIII ; Monoclonal antibody
Sažetak
Plasma-derived blood coagulation factor VIII was analyzed in real time using biosensor technology. Monoclonal antibodies directed against the heavy and against the light chain of factor VIII were immobilized on different carboxymethyl dextran surfaces. Different factor VIII concentrations were injected over the antibody surfaces in parallel and response levels were determined from the dissociation phase at a fixed time after sample injection. Serial dilutions of plasma-derived factor VIII with known concentrations determined by a commercial FVIIIC:Ag ELISA were used as standards. A quantification limit of 0.9 I.U./ml with antibody 530p and 1.5 I.U./ml with antibody 531p was calculated. Intra-assay precision expressed as percent coefficient of variation was below 10% for concentrations above 0.6 I.U./ml. Inter-assay precision for antibody 530p was below 20% for concentrations higher than 0.6 I.U./ml. For 531p, inter-assay precision was below 10% for concentrations higher than 2 I.U./ml. A sensor chip lifetime in respect to regeneration of at least 100 cycles for both antibodies was found. The small sample requirement of 35 μl allows fast analysis of different FVIII products and the use of two monoclonal antibodies directed against two different FVIII domains provides additional information about the integrity of the FVIII molecule.
Izvorni jezik
Engleski
Znanstvena područja
Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)
POVEZANOST RADA
Ustanove:
Sveučilište u Rijeci - Odjel za biotehnologiju
Profili:
Đuro Josić
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus