Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 990387

Comparison of microscale cleaning procedures for (Glyco) proteins prior to positive ion matrix-assisted laser desorption ionization mass spectrometry


Linnemayr, Katharina; Rizzi, Andreas; Josic, Djuro; Allmaier, Günter
Comparison of microscale cleaning procedures for (Glyco) proteins prior to positive ion matrix-assisted laser desorption ionization mass spectrometry // Analytica Chimica Acta, 372 (1998), 1-2; 187-199 doi:10.1016/s0003-2670(98)00345-6 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 990387 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparison of microscale cleaning procedures for (Glyco) proteins prior to positive ion matrix-assisted laser desorption ionization mass spectrometry

Autori
Linnemayr, Katharina ; Rizzi, Andreas ; Josic, Djuro ; Allmaier, Günter

Izvornik
Analytica Chimica Acta (0003-2670) 372 (1998), 1-2; 187-199

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
MALDI mass spectrometry ; Glycoprotein ; Protein ; Desalting ; Drop dialysis ; Gelfiltration ; Ultrafiltration ; Reverse phase adsorption

Sažetak
Microscale cleaning procedures for peptides, proteins and glycoproteins prior to matrix-assisted laser desorption ionization (MALDI) mass spectrometric (MS) analysis, based on different mechanisms – drop dialysis, ultrafiltration, reverse phase adsorption and gelfiltration, are being compared. The selected standard (glyco) proteins cover the mass range of 5000–70 000 Da. Individual components and mixtures containing up to five components have been used for the investigation. Five different procedures were applied and evaluated with regard to a subsequent positive ion MALDI time-of-flight MS analysis, which requires samples with relative low salt/buffer content. All methods were adapted for protein samples in the low picomole range. Drop dialysis, ultrafiltration, reverse phase adsorption in two different forms and gelfiltration are shown to be useful for proteins and partially for peptides and glycoproteins. It turned out that glycoproteins are more difficult to handle, due to the relatively high sample losses during the desalting procedures. Gelfiltration and reverse phase adsorption are the least time consuming methods, whereas drop dialysis and ultrafiltration are well suited for working on many samples in parallel. However, reverse phase adsorption and ultrafiltration offer the highest enrichment factors. For proteins available only in large sample volumes gelfiltration and reverse phase adsorption are the methods of choice.

Izvorni jezik
Engleski

Znanstvena područja
Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)



POVEZANOST RADA


Ustanove:
Sveučilište u Rijeci - Odjel za biotehnologiju

Profili:

Avatar Url Đuro Josić (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Linnemayr, Katharina; Rizzi, Andreas; Josic, Djuro; Allmaier, Günter
Comparison of microscale cleaning procedures for (Glyco) proteins prior to positive ion matrix-assisted laser desorption ionization mass spectrometry // Analytica Chimica Acta, 372 (1998), 1-2; 187-199 doi:10.1016/s0003-2670(98)00345-6 (međunarodna recenzija, članak, znanstveni)
Linnemayr, K., Rizzi, A., Josic, D. & Allmaier, G. (1998) Comparison of microscale cleaning procedures for (Glyco) proteins prior to positive ion matrix-assisted laser desorption ionization mass spectrometry. Analytica Chimica Acta, 372 (1-2), 187-199 doi:10.1016/s0003-2670(98)00345-6.
@article{article, author = {Linnemayr, Katharina and Rizzi, Andreas and Josic, Djuro and Allmaier, G\"{u}nter}, year = {1998}, pages = {187-199}, DOI = {10.1016/s0003-2670(98)00345-6}, keywords = {MALDI mass spectrometry, Glycoprotein, Protein, Desalting, Drop dialysis, Gelfiltration, Ultrafiltration, Reverse phase adsorption}, journal = {Analytica Chimica Acta}, doi = {10.1016/s0003-2670(98)00345-6}, volume = {372}, number = {1-2}, issn = {0003-2670}, title = {Comparison of microscale cleaning procedures for (Glyco) proteins prior to positive ion matrix-assisted laser desorption ionization mass spectrometry}, keyword = {MALDI mass spectrometry, Glycoprotein, Protein, Desalting, Drop dialysis, Gelfiltration, Ultrafiltration, Reverse phase adsorption} }
@article{article, author = {Linnemayr, Katharina and Rizzi, Andreas and Josic, Djuro and Allmaier, G\"{u}nter}, year = {1998}, pages = {187-199}, DOI = {10.1016/s0003-2670(98)00345-6}, keywords = {MALDI mass spectrometry, Glycoprotein, Protein, Desalting, Drop dialysis, Gelfiltration, Ultrafiltration, Reverse phase adsorption}, journal = {Analytica Chimica Acta}, doi = {10.1016/s0003-2670(98)00345-6}, volume = {372}, number = {1-2}, issn = {0003-2670}, title = {Comparison of microscale cleaning procedures for (Glyco) proteins prior to positive ion matrix-assisted laser desorption ionization mass spectrometry}, keyword = {MALDI mass spectrometry, Glycoprotein, Protein, Desalting, Drop dialysis, Gelfiltration, Ultrafiltration, Reverse phase adsorption} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font