Verification of Minicollect Z serum tubes with and without gel


Herceg, Ivona; Ćelap, Ivana; Nikolac Gabaj, Nora; Božović, Marija; Vrtarić, Alen; Topić, Anita; Krtanjek, Sanja
Verification of Minicollect Z serum tubes with and without gel // Clinical Chemistry and Laboratory Medicine / Plabani, Mario (ur.).
Berlin: Walter de Gruyter, 2019. str. eA15-eA15 doi:10.1515/cclm-2019-0104 (poster, međunarodna recenzija, sažetak, stručni)


CROSBI ID: 990210 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Verification of Minicollect Z serum tubes with and without gel

Autori
Herceg, Ivona ; Ćelap, Ivana ; Nikolac Gabaj, Nora ; Božović, Marija ; Vrtarić, Alen ; Topić, Anita ; Krtanjek, Sanja

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
Clinical Chemistry and Laboratory Medicine / Plabani, Mario - Berlin : Walter de Gruyter, 2019, EA15-eA15

Skup
5th EFLM Conference on Preanalytical Phase

Mjesto i datum
Zagreb, Hrvatska, 22.03.2019. - 23.03.2019

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Minicollect® tube, new model, verification

Sažetak
BACKGROUND-AIM: Minicollect® Z tubes manufacturer has developed a new tube containing same composition, different shape and better features compared to the old one. Therefore, they need to be verified before introduction into routine work. METHODS: Our study included comparison as follows: 1. qualitative comparison of serum separation ease ; 2. hemolysis degree comparison ; 3. comparison of 14 biochemical parameters (ALT, AMY, AST, direct bilirubin, total bilirubin, Ca, CK, Na, K, Cl, CRP, Glc, enzymatic creatinine, LD) and serum indices (H-hemolysis, I-icteria, L-lipemia). First comparison was done between old and new Minicollect® Z Serum tube (Greiner Bio-One, Kremmsmunster, Austria) (N = 30) and second between new Minicollect® Z Serum and a new Minicollect® Z Serum (Separator-with gel) tube (N = 40). Samples were centrifuged at 12100g/5 min and analyzed on Abbott Architect c8000 (Abbott Laboratories, Abbott Park, Illinois, USA). Sample was considered hemolysed if H index was >0.5. Bland-Altman plots were calculated using Medcalc® v18.10.2 (Ostend, Belgium). Bland- Altman plots derived biases were compared to Westgard’s minimum specification for allowable total error. RESULTS: New tube has an integrated collection scoop and is wider compared to the old one, resulting in easier sampling but lower serum column which makes aliquoting more difficult. However, it’s easier to separate serum in gel tube than from the one without gel. Hemolysed samples proportion didn’t differ between old (7/30) and new (10/30) tubes without gel, P = 0.748, as well between tubes without (9/40) and with gel (16/40), P = 0.148. Proportional bias for AMY (26.3% ; agreement range:-62.8% to 115.3 %) exceeds Westgard’s criteria (21.9%). CONCLUSIONS: Study showed that old tube and gel tube are better for serum separation compared to the new tube and tube without gel. AMY activity is higher in old tubes and possible cause should be tested in further investigations. Finally, gel tube is more appropriate for our routine laboratory work.

Izvorni jezik
Engleski



POVEZANOST RADA


Ustanove:
KBC "Sestre Milosrdnice"

Profili:

Avatar Url Ivana Ćelap (autor)

Avatar Url Alen Vrtarić (autor)

Avatar Url Anita Radman (autor)

Avatar Url Nora Nikolac (autor)

Poveznice na cjeloviti tekst rada:

doi www.degruyter.com

Citiraj ovu publikaciju:

Herceg, Ivona; Ćelap, Ivana; Nikolac Gabaj, Nora; Božović, Marija; Vrtarić, Alen; Topić, Anita; Krtanjek, Sanja
Verification of Minicollect Z serum tubes with and without gel // Clinical Chemistry and Laboratory Medicine / Plabani, Mario (ur.).
Berlin: Walter de Gruyter, 2019. str. eA15-eA15 doi:10.1515/cclm-2019-0104 (poster, međunarodna recenzija, sažetak, stručni)
Herceg, I., Ćelap, I., Nikolac Gabaj, N., Božović, M., Vrtarić, A., Topić, A. & Krtanjek, S. (2019) Verification of Minicollect Z serum tubes with and without gel. U: Plabani, M. (ur.)Clinical Chemistry and Laboratory Medicine doi:10.1515/cclm-2019-0104.
@article{article, author = {Herceg, Ivona and \'{C}elap, Ivana and Nikolac Gabaj, Nora and Bo\v{z}ovi\'{c}, Marija and Vrtari\'{c}, Alen and Topi\'{c}, Anita and Krtanjek, Sanja}, editor = {Plabani, M.}, year = {2019}, pages = {eA15-eA15}, DOI = {10.1515/cclm-2019-0104}, keywords = {Minicollect® tube, new model, verification}, doi = {10.1515/cclm-2019-0104}, title = {Verification of Minicollect Z serum tubes with and without gel}, keyword = {Minicollect® tube, new model, verification}, publisher = {Walter de Gruyter}, publisherplace = {Zagreb, Hrvatska} }
@article{article, author = {Herceg, Ivona and \'{C}elap, Ivana and Nikolac Gabaj, Nora and Bo\v{z}ovi\'{c}, Marija and Vrtari\'{c}, Alen and Topi\'{c}, Anita and Krtanjek, Sanja}, editor = {Plabani, M.}, year = {2019}, pages = {eA15-eA15}, DOI = {10.1515/cclm-2019-0104}, keywords = {Minicollect® tube, new model, verification}, doi = {10.1515/cclm-2019-0104}, title = {Verification of Minicollect Z serum tubes with and without gel}, keyword = {Minicollect® tube, new model, verification}, publisher = {Walter de Gruyter}, publisherplace = {Zagreb, Hrvatska} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font