Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 990004

A Position-Sensitive Detector System with Subnanosecond Timing and its Utilization in the Measurement of Pion Absorption


Petković, Tomislav; Backenstoss, G.; Cierjacks, S.; Furić, Miroslav; Izycki, M.; Ljungfelt, S.; Salvisberg, P.; Steinacher, M.; Ullrich, Horst; Weber, P.; Weyer H.J.
A Position-Sensitive Detector System with Subnanosecond Timing and its Utilization in the Measurement of Pion Absorption // Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 273 (1988), 2-3; 833-840 doi:10.1016/0168-9002(88)90104-0 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 990004 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
A Position-Sensitive Detector System with Subnanosecond Timing and its Utilization in the Measurement of Pion Absorption

Autori
Petković, Tomislav ; Backenstoss, G. ; Cierjacks, S. ; Furić, Miroslav ; Izycki, M. ; Ljungfelt, S. ; Salvisberg, P. ; Steinacher, M. ; Ullrich, Horst ; Weber, P. ; Weyer H.J.

Izvornik
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (0168-9002) 273 (1988), 2-3; 833-840

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Position sensitive Detector System with nanosecond timing

Sažetak
A complex position-sensitive, time-of-flight detector was designed at the SIN to be used in the kinematically complete measurements of pion absorption in light nuclei, for the detection of both neutrons and charged particles. Design parameters and TOF properties resulting from the computer calculations and suitable test measurements are given for the system consisting of 200 × 10 × 5 cm3 NE 102A scintillator bars, XP 2230 photomultipliers and discriminator. Position dependence of the timing parameters of the 2 m long NE 102A bar viewed from the ends by photomultipliers has been clearly revealed in our model and experimentally verified.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb,
Prirodoslovno-matematički fakultet, Zagreb

Profili:

Avatar Url Miroslav Furić (autor)

Avatar Url Tomislav Petković (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com

Citiraj ovu publikaciju:

Petković, Tomislav; Backenstoss, G.; Cierjacks, S.; Furić, Miroslav; Izycki, M.; Ljungfelt, S.; Salvisberg, P.; Steinacher, M.; Ullrich, Horst; Weber, P.; Weyer H.J.
A Position-Sensitive Detector System with Subnanosecond Timing and its Utilization in the Measurement of Pion Absorption // Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 273 (1988), 2-3; 833-840 doi:10.1016/0168-9002(88)90104-0 (međunarodna recenzija, članak, znanstveni)
Petković, T., Backenstoss, G., Cierjacks, S., Furić, M., Izycki, M., Ljungfelt, S., Salvisberg, P., Steinacher, M., Ullrich, H., Weber, P. & Weyer H.J. (1988) A Position-Sensitive Detector System with Subnanosecond Timing and its Utilization in the Measurement of Pion Absorption. Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 273 (2-3), 833-840 doi:10.1016/0168-9002(88)90104-0.
@article{article, author = {Petkovi\'{c}, Tomislav and Backenstoss, G. and Cierjacks, S. and Furi\'{c}, Miroslav and Izycki, M. and Ljungfelt, S. and Salvisberg, P. and Steinacher, M. and Ullrich, Horst and Weber, P.}, year = {1988}, pages = {833-840}, DOI = {10.1016/0168-9002(88)90104-0}, keywords = {Position sensitive Detector System with nanosecond timing}, journal = {Nuclear instruments and methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment}, doi = {10.1016/0168-9002(88)90104-0}, volume = {273}, number = {2-3}, issn = {0168-9002}, title = {A Position-Sensitive Detector System with Subnanosecond Timing and its Utilization in the Measurement of Pion Absorption}, keyword = {Position sensitive Detector System with nanosecond timing} }
@article{article, author = {Petkovi\'{c}, Tomislav and Backenstoss, G. and Cierjacks, S. and Furi\'{c}, Miroslav and Izycki, M. and Ljungfelt, S. and Salvisberg, P. and Steinacher, M. and Ullrich, Horst and Weber, P.}, year = {1988}, pages = {833-840}, DOI = {10.1016/0168-9002(88)90104-0}, keywords = {Position sensitive Detector System with nanosecond timing}, journal = {Nuclear instruments and methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment}, doi = {10.1016/0168-9002(88)90104-0}, volume = {273}, number = {2-3}, issn = {0168-9002}, title = {A Position-Sensitive Detector System with Subnanosecond Timing and its Utilization in the Measurement of Pion Absorption}, keyword = {Position sensitive Detector System with nanosecond timing} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font