Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 989821

Extraction of Triton X-100 and its determination in virus-inactivated human plasma by the solvent-detergent method


Strancar, Ales; Raspor, Peter; Schwinn, Horst; Schütz, Raimund; Josic, Djuro
Extraction of Triton X-100 and its determination in virus-inactivated human plasma by the solvent-detergent method // Journal of Chromatography A, 658 (1994), 2; 475-481 doi:10.1016/0021-9673(94)80038-3 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 989821 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Extraction of Triton X-100 and its determination in virus-inactivated human plasma by the solvent-detergent method

Autori
Strancar, Ales ; Raspor, Peter ; Schwinn, Horst ; Schütz, Raimund ; Josic, Djuro

Izvornik
Journal of Chromatography A (0021-9673) 658 (1994), 2; 475-481

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Human plasma ; Triton X-100 extraction ; Solvent-detergent method

Sažetak
For inactivation of lipid-enveloped viruses during the production of fresh frozen and lyophilized human plasma, the solvent-detergent method was applied. In this process, the solvent tri-n-butyl phosphate is removed by extraction with castor oil. The removal of the non-ionic detergent Triton X-100 is performed by solid-phase extraction using reversed-phase supports. For this purpose, different polymer- and silica-based supports were tested. The highest capacity for Triton X-100 was achieved with C18 silica gels. These supports can bind more than 0.1 ml of Triton X-100 per ml of support. None of the proteins, e.g., clotting factors, bind to the support and therefore they pass through the column and their biological activity is hardly affected. The determination of detergent during the production process was also studied. The application of special columns allowing direct sample injection was introduced. This is a simple method for the rapid in-process determination of Triton X-100 in human plasma by reversed-phase chromatography under isocratic conditions. Using the method developed here, less than 1.0 ppm of Triton X-100 can be detected in less than 12 min without any sample pretreatment.

Izvorni jezik
Engleski

Znanstvena područja
Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)



POVEZANOST RADA


Ustanove:
Sveučilište u Rijeci - Odjel za biotehnologiju

Profili:

Avatar Url Đuro Josić (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Strancar, Ales; Raspor, Peter; Schwinn, Horst; Schütz, Raimund; Josic, Djuro
Extraction of Triton X-100 and its determination in virus-inactivated human plasma by the solvent-detergent method // Journal of Chromatography A, 658 (1994), 2; 475-481 doi:10.1016/0021-9673(94)80038-3 (međunarodna recenzija, članak, znanstveni)
Strancar, A., Raspor, P., Schwinn, H., Schütz, R. & Josic, D. (1994) Extraction of Triton X-100 and its determination in virus-inactivated human plasma by the solvent-detergent method. Journal of Chromatography A, 658 (2), 475-481 doi:10.1016/0021-9673(94)80038-3.
@article{article, author = {Strancar, Ales and Raspor, Peter and Schwinn, Horst and Sch\"{u}tz, Raimund and Josic, Djuro}, year = {1994}, pages = {475-481}, DOI = {10.1016/0021-9673(94)80038-3}, keywords = {Human plasma, Triton X-100 extraction, Solvent-detergent method}, journal = {Journal of Chromatography A}, doi = {10.1016/0021-9673(94)80038-3}, volume = {658}, number = {2}, issn = {0021-9673}, title = {Extraction of Triton X-100 and its determination in virus-inactivated human plasma by the solvent-detergent method}, keyword = {Human plasma, Triton X-100 extraction, Solvent-detergent method} }
@article{article, author = {Strancar, Ales and Raspor, Peter and Schwinn, Horst and Sch\"{u}tz, Raimund and Josic, Djuro}, year = {1994}, pages = {475-481}, DOI = {10.1016/0021-9673(94)80038-3}, keywords = {Human plasma, Triton X-100 extraction, Solvent-detergent method}, journal = {Journal of Chromatography A}, doi = {10.1016/0021-9673(94)80038-3}, volume = {658}, number = {2}, issn = {0021-9673}, title = {Extraction of Triton X-100 and its determination in virus-inactivated human plasma by the solvent-detergent method}, keyword = {Human plasma, Triton X-100 extraction, Solvent-detergent method} }

Časopis indeksira:


  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font