Pregled bibliografske jedinice broj: 987411
Performance and Empirical Analysis of Photovoltaic Modules Made of Different Technologies Using Capacity Evaluation Method
Performance and Empirical Analysis of Photovoltaic Modules Made of Different Technologies Using Capacity Evaluation Method // Tehnički vjesnik : znanstveno-stručni časopis tehničkih fakulteta Sveučilišta u Osijeku, 26 (2019), 6; 1585-1592 doi:10.17559/TV-20181003182104 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 987411 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Performance and Empirical Analysis of Photovoltaic Modules Made of Different Technologies Using Capacity Evaluation Method
Autori
Žnidarec, Matej ; Šljivac, Damir ; Došen, Dario
Izvornik
Tehnički vjesnik : znanstveno-stručni časopis tehničkih fakulteta Sveučilišta u Osijeku (1330-3651) 26
(2019), 6;
1585-1592
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
capacity evaluation method ; empirical analysis ; performance analysis ; photovoltaic module
Sažetak
Performance of 5 photovoltaic (PV) modules made of different technologies (monocrystalline silicon, polycrystalline silicon, amorphous silicon, copper indium selenide and heterojunction with intrinsic layer) is evaluated according to the short-term capacity evaluation method described in IEC TS 61724-2 standard. Measurements for the analysis are obtained from the data acquisition system developed by the Laboratory for Renewable Energy Sources at the Faculty of Electrical Engineering, Computer Science and Information Technology (FERIT) Osijek which is described in the paper. Results of the performance analysis according to the IEC TS 61724-2 standard indicate that the copper indium selenide PV module Solar Frontier SF150-S has the greatest performance, therefore it is the most suitable PV module for the micro-location of Osijek, Croatia with European humid continental climate. The lowest performance of all studied PV modules is achieved by polycrystalline silicon PV module Bisol BMU 250. Empirical analysis of the relations of various electrical and meteorological parameters is performed and dependencies are evaluated. In the last section, mathematical models of PV module efficiency in relation to the module temperature are derived based on empirical analysis of measurements.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike, računarstva i informacijskih tehnologija Osijek
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus