Pregled bibliografske jedinice broj: 984372
Effect of anisotropy of masonry on the behaviour of unreinforced and confined masonry walls under ground motion
Effect of anisotropy of masonry on the behaviour of unreinforced and confined masonry walls under ground motion // Engineering Design Applications / Öchsner, Andreas ; Altenbach, Holm (ur.).
Heidelberg: Springer, 2018. str. 173-183 doi:10.1007/978-3-319-79005-3
CROSBI ID: 984372 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Effect of anisotropy of masonry on the behaviour of unreinforced and confined masonry walls under ground motion
Autori
Smilovic Zulim, Marija ; Radnić, Jure ; Grgić, Nikola ; Baloević, Goran
Vrsta, podvrsta i kategorija rada
Poglavlja u knjigama, znanstveni
Knjiga
Engineering Design Applications
Urednik/ci
Öchsner, Andreas ; Altenbach, Holm
Izdavač
Springer
Grad
Heidelberg
Godina
2018
Raspon stranica
173-183
ISBN
978-3-319-79004-6
ISSN
1869-8433
Ključne riječi
masonry wall, ground motion, numerical model, effect of anisotropy
Sažetak
This paper presents the numerical test results of the effect of anisotropy on the behaviour of unreinforced and confined masonry walls under horizontal harmonic ground acceleration. Two-storey masonry walls with different lengths (3m, 6m, 12m) are analysed. The wall foundations are supported on a rigid base, with possibility of lifting. A non-linear macro model of masonry is used. Cases of strong masonry (high strength and stiffness) and weak masonry (low strength and stiffness) are analysed. Different coefficients of anisotropy of masonry ca (0.2, 0.4, 0.6, 1.0) are considered. The excitation period is tak-en to correspond to the fundamental period of the individual elastic wall. Hor-izontal displacements at the top of the walls, vertical stresses in masonry and concrete at the bottom of the walls and stresses in the longitudinal bars at the bottom of the vertical ring beams are shown for each analysed case. It is con-cluded that the ultimate bearing capacity and deformability of walls, as well as stresses in masonry, concrete and reinforcement under dynamic excitation significantly depend on the anisotropy of masonry. It is also concluded that, with the same coefficient of anisotropy, the behaviour of masonry walls de-pends on its type (unreinforced, confined), height to length ratio (0.5, 1.0, 2.0), and the quality of masonry (strong, weak).
Izvorni jezik
Engleski
Znanstvena područja
Građevinarstvo
POVEZANOST RADA
Projekti:
083-0000000-1538 - Eksperimentalna i numerička istraživanja potresne otpornosti građevina (Radnić, Jure, MZO ) ( CroRIS)
Ustanove:
Fakultet građevinarstva, arhitekture i geodezije, Split
Profili:
Nikola Grgić
(autor)
Goran Baloević
(autor)
Jure Radnić
(autor)
Marija Smilović Zulim
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Scopus