The Influence of Spatial Calibrations of Hyperspectral Line Scanners on the Accuracy of Geocoding of Hyperspectral Cube


Gajski, Dubravko; Šemanjski, Silvio; Krtalić, Andrija
The Influence of Spatial Calibrations of Hyperspectral Line Scanners on the Accuracy of Geocoding of Hyperspectral Cube // Book of Papers (International Symposium “Mine Action 2018”) / Adlešić, Đurđa (ur.).
Zagreb: Hrvatski centar za razminiranje - Centar za testiranje, razvoj i obuku (HCR-CTRO), 2018. str. 62-65 (poster, nije recenziran, cjeloviti rad (in extenso), stručni)


CROSBI ID: 982913 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The Influence of Spatial Calibrations of Hyperspectral Line Scanners on the Accuracy of Geocoding of Hyperspectral Cube

Autori
Gajski, Dubravko ; Šemanjski, Silvio ; Krtalić, Andrija

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), stručni

Izvornik
Book of Papers (International Symposium “Mine Action 2018”) / Adlešić, Đurđa - Zagreb : Hrvatski centar za razminiranje - Centar za testiranje, razvoj i obuku (HCR-CTRO), 2018, 62-65

Skup
The 15th International Symposium "Mine Action 2018"

Mjesto i datum
Slano, Hrvatska, 09.04.2018. - 12.04.2018

Vrsta sudjelovanja
Poster

Vrsta recenzije
Nije recenziran

Ključne riječi
hyperspectral scanner, spatial calibration, parametric geocoding, accuracy

Sažetak
Although calibration during geocoding process shows drastic improvements in achieved geocoding accuracy, the internal orientation error remains. In order to properly determine these errors, we must first of all know the mathematical model of mapping of the line sensor. The mathematical model of mapping of the line sensor has been expanded to account for the distortion of the lens in order to eliminate all systematic errors induced by displacement of the real sensor mapping plane from the ideal mathematical model of the central projection. After a mathematical model was established, a calibration of the hyperspectral scanner was performed in the laboratory, observing test samples from 5 different recording sites. Calibration elements are determined by airborne beam equation (BBA method).

Izvorni jezik
Engleski

Znanstvena područja
Interdisciplinarne prirodne znanosti, Geodezija



POVEZANOST RADA


Ustanove:
Geodetski fakultet, Zagreb

Profili:

Avatar Url Andrija Krtalić (autor)

Avatar Url Silvio Šemanjski (autor)

Avatar Url Dubravko Gajski (autor)

Poveznice na cjeloviti tekst rada:

www.ctro.hr

Citiraj ovu publikaciju:

Gajski, Dubravko; Šemanjski, Silvio; Krtalić, Andrija
The Influence of Spatial Calibrations of Hyperspectral Line Scanners on the Accuracy of Geocoding of Hyperspectral Cube // Book of Papers (International Symposium “Mine Action 2018”) / Adlešić, Đurđa (ur.).
Zagreb: Hrvatski centar za razminiranje - Centar za testiranje, razvoj i obuku (HCR-CTRO), 2018. str. 62-65 (poster, nije recenziran, cjeloviti rad (in extenso), stručni)
Gajski, D., Šemanjski, S. & Krtalić, A. (2018) The Influence of Spatial Calibrations of Hyperspectral Line Scanners on the Accuracy of Geocoding of Hyperspectral Cube. U: Adlešić, Đ. (ur.)Book of Papers (International Symposium “Mine Action 2018”).
@article{article, author = {Gajski, Dubravko and \v{S}emanjski, Silvio and Krtali\'{c}, Andrija}, editor = {Adle\v{s}i\'{c}, \DJ.}, year = {2018}, pages = {62-65}, keywords = {hyperspectral scanner, spatial calibration, parametric geocoding, accuracy}, title = {The Influence of Spatial Calibrations of Hyperspectral Line Scanners on the Accuracy of Geocoding of Hyperspectral Cube}, keyword = {hyperspectral scanner, spatial calibration, parametric geocoding, accuracy}, publisher = {Hrvatski centar za razminiranje - Centar za testiranje, razvoj i obuku (HCR-CTRO)}, publisherplace = {Slano, Hrvatska} }
@article{article, author = {Gajski, Dubravko and \v{S}emanjski, Silvio and Krtali\'{c}, Andrija}, editor = {Adle\v{s}i\'{c}, \DJ.}, year = {2018}, pages = {62-65}, keywords = {hyperspectral scanner, spatial calibration, parametric geocoding, accuracy}, title = {The Influence of Spatial Calibrations of Hyperspectral Line Scanners on the Accuracy of Geocoding of Hyperspectral Cube}, keyword = {hyperspectral scanner, spatial calibration, parametric geocoding, accuracy}, publisher = {Hrvatski centar za razminiranje - Centar za testiranje, razvoj i obuku (HCR-CTRO)}, publisherplace = {Slano, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font