Stability and homogeneity of whole blood samples in CROQALM haematology scheme


Ćelap, Ivana; Unić, Adriana; Hećimović, Ana; Lenicek Krleža, Jasna
Stability and homogeneity of whole blood samples in CROQALM haematology scheme // 4th EFLM-BD European Conference on Preanalytical Phase Amsterdam (NL) / Clinical Chemistry and Laboratory Medicine (CCLM), 55(4) / Plebani, Mario (ur.).
Berlin: Walter de Gruyter, 2017. 12635, 1 (poster, međunarodna recenzija, sažetak, stručni)


CROSBI ID: 979122 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Stability and homogeneity of whole blood samples in CROQALM haematology scheme

Autori
Ćelap, Ivana ; Unić, Adriana ; Hećimović, Ana ; Lenicek Krleža, Jasna

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
4th EFLM-BD European Conference on Preanalytical Phase Amsterdam (NL) / Clinical Chemistry and Laboratory Medicine (CCLM), 55(4) / Plebani, Mario - Berlin : Walter de Gruyter, 2017

Skup
4th EFLM-BD European Conference on Preanalytical Phase

Mjesto i datum
Amsterdam, Nizozemska, 24.03.2017. - 25.03.2017

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
stability ; homogeneity ; whole blood ; control samples

Sažetak
BACKGROUND-AIM: The observed impact of the commercial control material on discrepancies between different instruments in hematology has encouraged the Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) to improve hematology scheme by ensuring fresh blood for quality control. Because of its reduced stability it is very important to assure samples which are stable during analysis and homogenous across all prepared aliquots. The aim of the study was to show tested stability and homogeneity of homemade samples for CROQALM hematology scheme during 2016. METHODS: CROQALM hematology scheme is performed three times a year. Control sample for all rounds in 2016 was fresh blood from single donor with simulation of abnormal case in the second round by dilution. Donations, aliquots and testing were conducted in Croatian institute for transfusion medicine. Homogeneity and stability were tested on hematology analyzer (Ruby- Abbott/USA) for red blood cells (RBC), white blood cells (WBC) and platelets (PLT) according to ISO 13528:2005(E). Acceptance criteria for both homogeneity and stability was Ss ≤ 0.3*Q (Ss is between-samples standard deviation is standard deviation for proficiency testing based on CLIA Acceptable Test Performance Criteria. RESULTS: In three rounds during 2016 results of stability assessment have shown that the most unstable were WBC with stability varying from 48 to 72 hours. PLT were stable from 5 to 6 days and RBC 6 days. Stability was not altered when fresh sample was manipulated in order to simulate abnormal case. In all three cycles of CROQALM hematology scheme the homogeneity met the acceptance criteria. CONCLUSION: According to tested stability and in order to avoid impact of control material on participant’s results, samples must be delivered to all participants within 2 days after preparation and analyzed immediately upon receipt.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
KBC "Sestre Milosrdnice",
Hrvatski zavod za transfuzijsku medicinu,
Klinika za dječje bolesti

Profili:

Avatar Url Jasna Leniček Krleža (autor)

Avatar Url Adriana Unić (autor)

Avatar Url Ivana Ćelap (autor)

Poveznice na cjeloviti tekst rada:

www.degruyter.com www.researchgate.net

Citiraj ovu publikaciju:

Ćelap, Ivana; Unić, Adriana; Hećimović, Ana; Lenicek Krleža, Jasna
Stability and homogeneity of whole blood samples in CROQALM haematology scheme // 4th EFLM-BD European Conference on Preanalytical Phase Amsterdam (NL) / Clinical Chemistry and Laboratory Medicine (CCLM), 55(4) / Plebani, Mario (ur.).
Berlin: Walter de Gruyter, 2017. 12635, 1 (poster, međunarodna recenzija, sažetak, stručni)
Ćelap, I., Unić, A., Hećimović, A. & Lenicek Krleža, J. (2017) Stability and homogeneity of whole blood samples in CROQALM haematology scheme. U: Plebani, M. (ur.)4th EFLM-BD European Conference on Preanalytical Phase Amsterdam (NL) / Clinical Chemistry and Laboratory Medicine (CCLM), 55(4).
@article{article, author = {\'{C}elap, Ivana and Uni\'{c}, Adriana and He\'{c}imovi\'{c}, Ana and Lenicek Krle\v{z}a, Jasna}, editor = {Plebani, M.}, year = {2017}, pages = {1}, chapter = {12635}, keywords = {stability, homogeneity, whole blood, control samples}, title = {Stability and homogeneity of whole blood samples in CROQALM haematology scheme}, keyword = {stability, homogeneity, whole blood, control samples}, publisher = {Walter de Gruyter}, publisherplace = {Amsterdam, Nizozemska}, chapternumber = {12635} }
@article{article, author = {\'{C}elap, Ivana and Uni\'{c}, Adriana and He\'{c}imovi\'{c}, Ana and Lenicek Krle\v{z}a, Jasna}, editor = {Plebani, M.}, year = {2017}, pages = {1}, chapter = {12635}, keywords = {stability, homogeneity, whole blood, control samples}, title = {Stability and homogeneity of whole blood samples in CROQALM haematology scheme}, keyword = {stability, homogeneity, whole blood, control samples}, publisher = {Walter de Gruyter}, publisherplace = {Amsterdam, Nizozemska}, chapternumber = {12635} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font