Islanding Detection of Synchronous Generator-Based DGs using Rate of Change of Reactive Power


Nikolovski, Srete; Hamid, Reza, Baghaee; Dragan Mlakić
Islanding Detection of Synchronous Generator-Based DGs using Rate of Change of Reactive Power // IEEE Systems Journal, 13 (2019), 1; 1-11 doi:10.1109/JSYST.2018.2889981 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 979020 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Islanding Detection of Synchronous Generator-Based DGs using Rate of Change of Reactive Power

Autori
Nikolovski, Srete ; Hamid, Reza, Baghaee ; Dragan Mlakić

Izvornik
IEEE Systems Journal (1932-8184) 13 (2019), 1; 1-11

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Automatic voltage regulator ; bio-mass power plant ; islanding detection ; reactive power ; synchronous generator

Sažetak
The question of the islanding operation of distributed generations (DGs) and that of the current inadmissible networking policy of islanding operations sets a demanding task for an efficient islanding detection, preferably from a single place, using either passive or active islanding-detection method. Islanding detection shall be faster than the fast automatic reclosing of the connected transmission line connected to the DG unit. This paper deals with the detection method of islanded operation mode for the large power synchronous generator-based DGs in bio-mass power plants. The proposed method has been applied to a practical 10-MW bio-mass power plant and experimentally tested to verify the simulation results. The rate of change of reactive power (dQ/dt >) criterion is derived as a yardstick for islanding detection. The practical power plant model has been implemented to be simulated in DIgSILENT PowerFactory and MATLAB/Simulink software environments. Offline digital time-domain simulations and experimental tests on a practical bio-mass power plant reveals that the proposed method efficiently, and authentically detects islanding phenomena with high accuracy, low detection time, very small number of non-detected zones and, with almost zero power balance (ΔP = 0).

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike, računarstva i informacijskih tehnologija Osijek

Profili:

Avatar Url Paolo Dragan (autor)

Avatar Url Srete Nikolovski (autor)

Poveznice na cjeloviti tekst rada:

doi ieeexplore.ieee.org

Citiraj ovu publikaciju:

Nikolovski, Srete; Hamid, Reza, Baghaee; Dragan Mlakić
Islanding Detection of Synchronous Generator-Based DGs using Rate of Change of Reactive Power // IEEE Systems Journal, 13 (2019), 1; 1-11 doi:10.1109/JSYST.2018.2889981 (međunarodna recenzija, članak, znanstveni)
Nikolovski, S., Hamid, Reza, Baghaee & Dragan Mlakić (2019) Islanding Detection of Synchronous Generator-Based DGs using Rate of Change of Reactive Power. IEEE Systems Journal, 13 (1), 1-11 doi:10.1109/JSYST.2018.2889981.
@article{article, author = {Nikolovski, Srete}, year = {2019}, pages = {1-11}, DOI = {10.1109/JSYST.2018.2889981}, keywords = {Automatic voltage regulator, bio-mass power plant, islanding detection, reactive power, synchronous generator}, journal = {IEEE Systems Journal}, doi = {10.1109/JSYST.2018.2889981}, volume = {13}, number = {1}, issn = {1932-8184}, title = {Islanding Detection of Synchronous Generator-Based DGs using Rate of Change of Reactive Power}, keyword = {Automatic voltage regulator, bio-mass power plant, islanding detection, reactive power, synchronous generator} }
@article{article, author = {Nikolovski, Srete}, year = {2019}, pages = {1-11}, DOI = {10.1109/JSYST.2018.2889981}, keywords = {Automatic voltage regulator, bio-mass power plant, islanding detection, reactive power, synchronous generator}, journal = {IEEE Systems Journal}, doi = {10.1109/JSYST.2018.2889981}, volume = {13}, number = {1}, issn = {1932-8184}, title = {Islanding Detection of Synchronous Generator-Based DGs using Rate of Change of Reactive Power}, keyword = {Automatic voltage regulator, bio-mass power plant, islanding detection, reactive power, synchronous generator} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)