Setup for measuring and simulating high-frequency overvoltages of power transformer


Jurišić, Bruno; Filipović-Grčić, Božidar; Župan, Tomislav; Teklić, Ljupko
Setup for measuring and simulating high-frequency overvoltages of power transformer // Second International Colloquium on Smart Grid Metrology
Split, Hrvatska, 2019. str. 1-5 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 978791 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Setup for measuring and simulating high-frequency overvoltages of power transformer

Autori
Jurišić, Bruno ; Filipović-Grčić, Božidar ; Župan, Tomislav ; Teklić, Ljupko

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Second International Colloquium on Smart Grid Metrology / - , 2019, 1-5

Skup
Second International Colloquium on Smart Grid Metrology

Mjesto i datum
Split, Hrvatska, 09.04.2019. - 12.04.2019

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
transformer ; modelling ; frequency response ; overvoltages ; monitoring system

Sažetak
During their operation, power transformers are stressed by switching and lightning overvoltages. Transformers that are extensively exposed to these stresses are usually equipped with transformer monitoring system which enables assessing the transformer’s condition at any given time. Recorded data, taken from the transient recorder (a module of transformer monitoring system), can be used to evaluate the amplitude and frequency of overvoltage occurrence for a given transformer. These transformer monitoring systems can be applied to the shunt reactors as well. Furthermore, it is possible to use these data for advanced simulations of electromagnetic transients in EMTP-type software in order to check the influence of overvoltages on transformers and neighboring components. Wide-band transformer models have to be used for these simulations. In this paper, a transformer model based on frequency dependent admittance matrix measurements is described, as well as the example of transformer monitoring system data analysis.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika

Napomena
Rad poslan na recenziju.



POVEZANOST RADA


Ustanove:
KONČAR - Institut za elektrotehniku d.d.,
Fakultet elektrotehnike i računarstva, Zagreb

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada

Citiraj ovu publikaciju:

Jurišić, Bruno; Filipović-Grčić, Božidar; Župan, Tomislav; Teklić, Ljupko
Setup for measuring and simulating high-frequency overvoltages of power transformer // Second International Colloquium on Smart Grid Metrology
Split, Hrvatska, 2019. str. 1-5 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Jurišić, B., Filipović-Grčić, B., Župan, T. & Teklić, L. (2019) Setup for measuring and simulating high-frequency overvoltages of power transformer. U: Second International Colloquium on Smart Grid Metrology.
@article{article, author = {Juri\v{s}i\'{c}, Bruno and Filipovi\'{c}-Gr\v{c}i\'{c}, Bo\v{z}idar and \v{Z}upan, Tomislav and Tekli\'{c}, Ljupko}, year = {2019}, pages = {1-5}, keywords = {transformer, modelling, frequency response, overvoltages, monitoring system}, title = {Setup for measuring and simulating high-frequency overvoltages of power transformer}, keyword = {transformer, modelling, frequency response, overvoltages, monitoring system}, publisherplace = {Split, Hrvatska} }
@article{article, author = {Juri\v{s}i\'{c}, Bruno and Filipovi\'{c}-Gr\v{c}i\'{c}, Bo\v{z}idar and \v{Z}upan, Tomislav and Tekli\'{c}, Ljupko}, year = {2019}, pages = {1-5}, keywords = {transformer, modelling, frequency response, overvoltages, monitoring system}, title = {Setup for measuring and simulating high-frequency overvoltages of power transformer}, keyword = {transformer, modelling, frequency response, overvoltages, monitoring system}, publisherplace = {Split, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font