Pregled bibliografske jedinice broj: 968988
Thermographic monitoring of Thermographic monitoring of temperature changes in mini dental implant overdenture patients
Thermographic monitoring of Thermographic monitoring of temperature changes in mini dental implant overdenture patients // EPA-SEPES Digital natives in prosthodontics / European Prosthodontic Association
Madrid: European Pressphoto Agency (EPA), 2018. str. 172-172 (poster, podatak o recenziji nije dostupan, sažetak, znanstveni)
CROSBI ID: 968988 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Thermographic monitoring of Thermographic
monitoring of temperature changes in mini dental
implant overdenture patients
(Thermographic monitoring of temperature changes in
mini dental implant overdenture patients)
Autori
Kovačić, Ines ; Batinjan, Goran ; Peršić, Sanja ; Filipović- Zore, Irina ; Kranjčić Josip ; Čelebić, Asja
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
EPA-SEPES Digital natives in prosthodontics / European Prosthodontic Association
/ - Madrid : European Pressphoto Agency (EPA), 2018, 172-172
Skup
42nd Annual Conference of the European Prosthodontic Association (EPA) and EPA-SEPES joint meeting
Mjesto i datum
Madrid, Španjolska, 13.09.2018. - 15.09.2018
Vrsta sudjelovanja
Poster
Vrsta recenzije
Podatak o recenziji nije dostupan
Ključne riječi
thermography ; complete denture ; mini dental implants ; gingiva temperature
Sažetak
Objectives: To identify intraoral areas defined by thermal gradient and measure temperature differences of the mucosa under removable overdentures after performing chewing tasks with and without mini dental implant (MDI) loading. Methods: Each of 20 completely edentulous patients received 4 MDI in the mandible. Implants were immediately loaded. Patients were fully adapted to their dentures (3-12 months of wearing after all adjustments finished). Recordings with thermal camera were made: 1. Referent temperature was obtained at resting (dentures in mouth 15 minutes without occlusal contacts), 2. Immediately after 10 minutes of cotton-roll chewing task, and 3. After chewing task till the temperature dropped to reference value. The same procedure was repeated with same overdentures, but after matrices (retention caps) had been removed and the respective dentures turned into mucosa- borne dentures. Results: Temperature increased significantly after chewing task and remained almost constant throughout the first minute after denture removal. It took almost 3 minutes to return to the reference temperature. With mucosa borne overdentures (matrices removed) temperature increased to 37.7°C±1.2°C, while with MDI loaded overdentures (matrices mounted) temperature increased to 36.8°C±0.9° C. The area close to MDIs did not heat up with matrices mounted. In both cases the highest temperature was recorded in posterior denture-borne areas. It took a bit longer (p<0.05) till the temperature dropped down to the reference value with mucosa-borne overdenture (matrices removed). Conclusion: The temperature of the mucosa under dentures increased less after chewing tasks when MDIs were loaded.
Izvorni jezik
Engleski
Znanstvena područja
Dentalna medicina
POVEZANOST RADA
Ustanove:
Stomatološki fakultet, Zagreb
Profili:
Ines Kovačić
(autor)
Goran Batinjan
(autor)
Asja Čelebić
(autor)
Josip Kranjčić
(autor)
Irina Filipović Zore
(autor)
Sanja Peršić Kiršić
(autor)