Laboratory Test Bed for Analyzing Fault-Detection Reaction Times of Protection Relays in Different Substation Topologies


Jurišić, Goran; Havelka, Juraj; Capuder, Tomislav; Sučić, Stjepan
Laboratory Test Bed for Analyzing Fault-Detection Reaction Times of Protection Relays in Different Substation Topologies // Energies, 11 (2018), 9; 2482-2495 doi:10.3390/en11092482 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 965530 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Laboratory Test Bed for Analyzing Fault-Detection Reaction Times of Protection Relays in Different Substation Topologies

Autori
Jurišić, Goran ; Havelka, Juraj ; Capuder, Tomislav ; Sučić, Stjepan

Izvornik
Energies (1996-1073) 11 (2018), 9; 2482-2495

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
digital substation ; generic object-oriented substation event (GOOSE) ; International Electrotechnical Commission (IEC) 61850 ; intelligent electronics device (IED) ; merging unit ; relay protection ; substation configuration language (SCL)

Sažetak
Visions of energy transition focus on activating end users, meaning that numerous flexible- distribution network-level devices become active participants in power-system operations. This implies a fast, reliable, and secure exchange of data, enabling the distribution-system operators to maintain, or even improve, the quality and delivery of service. With the introduction of the International Electrotechnical Commission (IEC) 61850 standard, the path is set for a single communication topology covering all substation levels. The standard has the potential to change the way substations are designed, built, tested, and maintained. This means that the key segment of the substation, its protection system, will go through a transition period with the end goal of having a digitized substation where all information exchange is performed over an Ethernet communication bus. This paper analyzes the performance impact of the IEC 61850-9-2LE on the protection system. To do this, a laboratory hardware-in-the-loop test setup was developed representing traditional-, hybrid-, and digital- substation topology. The setup serves to simulate faults and create transient waveforms in an extended IEEE 123-node test system, which is then used to detect the reaction times of protection relay devices. To verify the results, a significant number of tests was performed clearly showing the benefits of digitalizing the distribution system.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Tomislav Capuder (autor)

Avatar Url Juraj Havelka (autor)

Poveznice na cjeloviti tekst rada:

doi www.mdpi.com doi.org

Citiraj ovu publikaciju:

Jurišić, Goran; Havelka, Juraj; Capuder, Tomislav; Sučić, Stjepan
Laboratory Test Bed for Analyzing Fault-Detection Reaction Times of Protection Relays in Different Substation Topologies // Energies, 11 (2018), 9; 2482-2495 doi:10.3390/en11092482 (međunarodna recenzija, članak, znanstveni)
Jurišić, G., Havelka, J., Capuder, T. & Sučić, S. (2018) Laboratory Test Bed for Analyzing Fault-Detection Reaction Times of Protection Relays in Different Substation Topologies. Energies, 11 (9), 2482-2495 doi:10.3390/en11092482.
@article{article, author = {Juri\v{s}i\'{c}, Goran and Havelka, Juraj and Capuder, Tomislav and Su\v{c}i\'{c}, Stjepan}, year = {2018}, pages = {2482-2495}, DOI = {10.3390/en11092482}, keywords = {digital substation, generic object-oriented substation event (GOOSE), International Electrotechnical Commission (IEC) 61850, intelligent electronics device (IED), merging unit, relay protection, substation configuration language (SCL)}, journal = {Energies}, doi = {10.3390/en11092482}, volume = {11}, number = {9}, issn = {1996-1073}, title = {Laboratory Test Bed for Analyzing Fault-Detection Reaction Times of Protection Relays in Different Substation Topologies}, keyword = {digital substation, generic object-oriented substation event (GOOSE), International Electrotechnical Commission (IEC) 61850, intelligent electronics device (IED), merging unit, relay protection, substation configuration language (SCL)} }
@article{article, author = {Juri\v{s}i\'{c}, Goran and Havelka, Juraj and Capuder, Tomislav and Su\v{c}i\'{c}, Stjepan}, year = {2018}, pages = {2482-2495}, DOI = {10.3390/en11092482}, keywords = {digital substation, generic object-oriented substation event (GOOSE), International Electrotechnical Commission (IEC) 61850, intelligent electronics device (IED), merging unit, relay protection, substation configuration language (SCL)}, journal = {Energies}, doi = {10.3390/en11092482}, volume = {11}, number = {9}, issn = {1996-1073}, title = {Laboratory Test Bed for Analyzing Fault-Detection Reaction Times of Protection Relays in Different Substation Topologies}, keyword = {digital substation, generic object-oriented substation event (GOOSE), International Electrotechnical Commission (IEC) 61850, intelligent electronics device (IED), merging unit, relay protection, substation configuration language (SCL)} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Uključenost u ostale bibliografske baze podataka::


  • AGRIS International
  • CA Search (Chemical Abstracts)
  • CAB Abstracts
  • Compendex (EI Village)
  • AGORA
  • DOAJ
  • EconPapers
  • ETDE
  • Genamics
  • HINARI
  • IDEAS (RePEc)external link
  • INSPEC
  • JCReports/ Science Edition
  • Julkaisufoorumi Publication Forum
  • LAPSE
  • Norwegian Register for Scientific Journals
  • Series and Publishers (NSD)external link
  • RePEcexternal link


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font