Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 964802

Electroanalytical determination of cysteine using the electrodes based on ternary silver-copper sulphides


Vladislavić, Nives; Škugor Rončević Ivana; Buljac Maša; Brinić Slobodan; Krivić Denis; Buzuk Marijo
Electroanalytical determination of cysteine using the electrodes based on ternary silver-copper sulphides // Sensors, 18 (2018), 11; 3753, 17 doi:10.3390/s18113753 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 964802 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Electroanalytical determination of cysteine using the electrodes based on ternary silver-copper sulphides

Autori
Vladislavić, Nives ; Škugor Rončević Ivana ; Buljac Maša ; Brinić Slobodan ; Krivić Denis ; Buzuk Marijo

Izvornik
Sensors (1424-8220) 18 (2018), 11; 3753, 17

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
cysteine ; determination ; silver-copper sulfides ; amperometry ; electrochemical ; impedance spectroscopy ; FTIR ; electroanalysis

Sažetak
The amperometric determination of cysteine, using an electrode based on ternary silver-copper sulphide, is presented. Electrochemical characterizations (using cyclic voltammetry) of three electrode materials revealed that the electrode based on the material that consists of jalpaite (Ag3CuS2), doped with a small amount of metallic silver, has the best electrocatalytical performance for cysteine oxidation. For the amperometric determination, 0.142 V at pH 5 and 0.04 V at pH 7 vs. Ag/AgCl, related to the electrocatalytical oxidation of thiol group, were chosen. Electrochemical impedance spectroscopy together with Fourier transform infrared spectroscopy (FTIR) revealed that oxidation takes place on the electrode surface with fouling effect, which does not affect a wide linear working range between 1 μM and 100 μM. Sensitivities, at pH 5 and pH 7, are calculated to be 0.11 μA μM-1 and 0.10 μA μM-1, respectively. The detection limits were determined to be 0.036 μM and 0.024 μM for pH 5 and pH 7, respectively. In the presence of uric acid, folic acid, ascorbic acid and glucose no interference was noticed. This electrode showed remarkable stability and excellent reproducibility. The electrode was exploited for the determination of cysteine in a dietary supplement with the excellent recoveries.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Ustanove:
Kemijsko-tehnološki fakultet, Split

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Vladislavić, Nives; Škugor Rončević Ivana; Buljac Maša; Brinić Slobodan; Krivić Denis; Buzuk Marijo
Electroanalytical determination of cysteine using the electrodes based on ternary silver-copper sulphides // Sensors, 18 (2018), 11; 3753, 17 doi:10.3390/s18113753 (međunarodna recenzija, članak, znanstveni)
Vladislavić, N., Škugor Rončević Ivana, Buljac Maša, Brinić Slobodan, Krivić Denis & Buzuk Marijo (2018) Electroanalytical determination of cysteine using the electrodes based on ternary silver-copper sulphides. Sensors, 18 (11), 3753, 17 doi:10.3390/s18113753.
@article{article, author = {Vladislavi\'{c}, Nives}, year = {2018}, pages = {17}, DOI = {10.3390/s18113753}, chapter = {3753}, keywords = {cysteine, determination, silver-copper sulfides, amperometry, electrochemical, impedance spectroscopy, FTIR, electroanalysis}, journal = {Sensors}, doi = {10.3390/s18113753}, volume = {18}, number = {11}, issn = {1424-8220}, title = {Electroanalytical determination of cysteine using the electrodes based on ternary silver-copper sulphides}, keyword = {cysteine, determination, silver-copper sulfides, amperometry, electrochemical, impedance spectroscopy, FTIR, electroanalysis}, chapternumber = {3753} }
@article{article, author = {Vladislavi\'{c}, Nives}, year = {2018}, pages = {17}, DOI = {10.3390/s18113753}, chapter = {3753}, keywords = {cysteine, determination, silver-copper sulfides, amperometry, electrochemical, impedance spectroscopy, FTIR, electroanalysis}, journal = {Sensors}, doi = {10.3390/s18113753}, volume = {18}, number = {11}, issn = {1424-8220}, title = {Electroanalytical determination of cysteine using the electrodes based on ternary silver-copper sulphides}, keyword = {cysteine, determination, silver-copper sulfides, amperometry, electrochemical, impedance spectroscopy, FTIR, electroanalysis}, chapternumber = {3753} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font