Pregled bibliografske jedinice broj: 96287
Realization of the All-Pole Third-Order Transfer Function
Realization of the All-Pole Third-Order Transfer Function // Proceedings of the 9th International Conference on Electronics, Circuits and Systems ICECS 2002 / Dubrovnik, Croatia, September, 15-18, 2002 / Barić, A. ; Magjarević, R. ; Pejčinović, B. ; Chrzanowska-Jeske M. (ur.).
Dubrovnik: Institute of Electrical and Electronics Engineers (IEEE), 2002. str. 149-152 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 96287 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Realization of the All-Pole Third-Order Transfer Function
Autori
Dozet, Mirko ; Stojković, Nino
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 9th International Conference on Electronics, Circuits and Systems ICECS 2002 / Dubrovnik, Croatia, September, 15-18, 2002
/ Barić, A. ; Magjarević, R. ; Pejčinović, B. ; Chrzanowska-Jeske M. - Dubrovnik : Institute of Electrical and Electronics Engineers (IEEE), 2002, 149-152
Skup
The 9th International Conference on Electronics, Circuits and Systems ICECS 2002
Mjesto i datum
Dubrovnik, Hrvatska, 15.09.2002. - 18.09.2002
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Analog filters; Transfer functions; Ladder network; Cumulants
Sažetak
Realization possibilities of the all-pole third-order transfer functions are discussed. For this purpose, the ladder network with controlled voltage source in any shunt branch is used. The voltage source is controlled by shunt branch voltage. The transfer functions are expressed with cumulants. Because of high degree of symmetry, there are the rules for cumulant development. In this paper, the controlled voltage source with controlling voltage placed in shunt branch behind source is considered. In that case, the transfer function contains only poles. The realization of the all-pole third-order transfer function is given on example. The transfer function stability is analyzed using the Routh-Hurwitz criterion for the third degree polynomials.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika, Računarstvo
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb,
Tehnički fakultet, Rijeka