Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 960240

Complement-dependent cytotoxicity and Luminex technology for human leucocyte antigen antibody detection in kidney transplant candidates exposed to different sensitizing events


Katalinić, Nataša; Starčević, Alma; Mavrinac, Martina; Balen, Sanja
Complement-dependent cytotoxicity and Luminex technology for human leucocyte antigen antibody detection in kidney transplant candidates exposed to different sensitizing events // Clinical kidney journal, 10 (2017), 6; 852-858 doi:10.1093/ckj/sfx050 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 960240 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Complement-dependent cytotoxicity and Luminex technology for human leucocyte antigen antibody detection in kidney transplant candidates exposed to different sensitizing events

Autori
Katalinić, Nataša ; Starčević, Alma ; Mavrinac, Martina ; Balen, Sanja

Izvornik
Clinical kidney journal (2048-8505) 10 (2017), 6; 852-858

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
HLA antibodies ; HLA antibodies techniques ; kidney transplantation ; sensitization ; waiting list

Sažetak
Background: The aim of this study was to determine the frequency of exposure to different sensitizing events (SEs) and to assess their effects on human leucocyte antigen (HLA) alloimmunization in transplant candidates using two different HLA antibody screening techniques: complement- dependent cytotoxicity (CDC) and Luminex. Methods: This retrospective study included HLA antibody screening results for 163 patients on the kidney transplant waiting list (WL) tested from March 2012 until the end of December 2015 at the Tissue Typing Laboratory, Rijeka, Croatia. All sera samples were tested using the CDC and Luminex techniques in parallel. Results: Two-thirds of the patients [114 (70%)] on the WL were exposed to transfusions, pregnancies and/or kidney transplant. The pre-transplant sera of 104 (63.80%) patients were negative for antibodies. In the sera of 23 (14.11%) patients, HLA antibodies were detected by CDC and Luminex and in the sera of 36 (22.09%) patients by Luminex only. Conclusion: In patients on kidney WL, previous organ transplantation represents the strongest immunogenic stimulus, followed by blood transfusions (the most frequent SE) and pregnancies. Although Luminex is more sensitive than CDC in HLA antibody detection, the decision on unacceptable HLA antigens in WL patients has to be based on the results of both assays and the patient’s immunization history.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Rijeka,
Medicinski fakultet, Osijek,
Klinički bolnički centar Rijeka

Profili:

Avatar Url Sanja Balen (autor)

Avatar Url Nataša Katalinić (autor)

Avatar Url Martina Mavrinac (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Katalinić, Nataša; Starčević, Alma; Mavrinac, Martina; Balen, Sanja
Complement-dependent cytotoxicity and Luminex technology for human leucocyte antigen antibody detection in kidney transplant candidates exposed to different sensitizing events // Clinical kidney journal, 10 (2017), 6; 852-858 doi:10.1093/ckj/sfx050 (međunarodna recenzija, članak, znanstveni)
Katalinić, N., Starčević, A., Mavrinac, M. & Balen, S. (2017) Complement-dependent cytotoxicity and Luminex technology for human leucocyte antigen antibody detection in kidney transplant candidates exposed to different sensitizing events. Clinical kidney journal, 10 (6), 852-858 doi:10.1093/ckj/sfx050.
@article{article, author = {Katalini\'{c}, Nata\v{s}a and Star\v{c}evi\'{c}, Alma and Mavrinac, Martina and Balen, Sanja}, year = {2017}, pages = {852-858}, DOI = {10.1093/ckj/sfx050}, keywords = {HLA antibodies, HLA antibodies techniques, kidney transplantation, sensitization, waiting list}, journal = {Clinical kidney journal}, doi = {10.1093/ckj/sfx050}, volume = {10}, number = {6}, issn = {2048-8505}, title = {Complement-dependent cytotoxicity and Luminex technology for human leucocyte antigen antibody detection in kidney transplant candidates exposed to different sensitizing events}, keyword = {HLA antibodies, HLA antibodies techniques, kidney transplantation, sensitization, waiting list} }
@article{article, author = {Katalini\'{c}, Nata\v{s}a and Star\v{c}evi\'{c}, Alma and Mavrinac, Martina and Balen, Sanja}, year = {2017}, pages = {852-858}, DOI = {10.1093/ckj/sfx050}, keywords = {HLA antibodies, HLA antibodies techniques, kidney transplantation, sensitization, waiting list}, journal = {Clinical kidney journal}, doi = {10.1093/ckj/sfx050}, volume = {10}, number = {6}, issn = {2048-8505}, title = {Complement-dependent cytotoxicity and Luminex technology for human leucocyte antigen antibody detection in kidney transplant candidates exposed to different sensitizing events}, keyword = {HLA antibodies, HLA antibodies techniques, kidney transplantation, sensitization, waiting list} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Emerging Sources Citation Index (ESCI)
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font