Real-Time Loss Calculation of a Hysteresis Controlled Power Converter
Real-Time Loss Calculation of a Hysteresis Controlled Power Converter // 3rd International Multidisciplinary Conference on Computer and Energy Science SpliTech 2018
Split, Hrvatska, 2018. str. 1-6 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 953384 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Real-Time Loss Calculation of a Hysteresis Controlled Power Converter
Autori
Bašić, Mateo ; Vukadinović, Dinko ; Grgić, Ivan
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Skup
3rd International Multidisciplinary Conference on Computer and Energy Science SpliTech 2018
Mjesto i datum
Split, Hrvatska, 26.06.2018. - 29.06.2018
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Hysteresis switching ; Loss calculation ; Power converter losses ; Rotor-field-oriented control ; Self-excited induction generator
Sažetak
This paper presents an algorithm for real-time calculation of losses of a hysteresis controlled power converter. The converter under consideration is a standard three-phase bridge converter, consisting of six insulated-gate bipolar transistors (IGBTs) and free-wheeling diodes. It is here utilized for vector control of a self-excited induction generator. The vector control algorithm requires measurement of two phase currents, rotor speed, and dc-link voltage. Application of the loss-calculation algorithm, on the other hand, requires knowledge of the dc-link voltage, one of the phase currents and IGBT switching signals. Hence, all three required inputs are already available, so no additional sensors need to be installed in order to implement the loss- calculation algorithm. The proposed algorithm allows the power converter losses to be determined both by type (switching/conduction losses) and device (IGBT/diode losses), thus enabling a more detailed loss analysis. In this paper, the power converter losses are determined over reasonably wide ranges of dc- link voltage and phase current values, and subsequently validated by comparison with the measured values.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
Napomena
Ovaj je rad financirala Hrvatska zaklada za znanost projektom (IP-2016-06-3319)
POVEZANOST RADA
Projekti:
HRZZ-IP-2016-06-3319 - Sustav vjetar-sunce za optimiziranu proizvodnju električne energije u rezidencijalnim objektima (WINDSOR) (Vukadinović, Dinko, HRZZ - 2016-06) ( CroRIS)
Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split