Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 945926

Implant's surface morphology and roughness influence on bonding with bone cement


Smolčić, Juraj; Stepić, Antonio; Kumić, Ivan
Implant's surface morphology and roughness influence on bonding with bone cement // MTECH INTERNATIONAL CONFERENCE ON MATERIALS
Zadar, Hrvatska, 2017. str. 341-350 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 945926 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Implant's surface morphology and roughness influence on bonding with bone cement

Autori
Smolčić, Juraj ; Stepić, Antonio ; Kumić, Ivan

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
MTECH INTERNATIONAL CONFERENCE ON MATERIALS / - , 2017, 341-350

Skup
MTECH INTERNATIONAL CONFERENCE ON MATERIALS

Mjesto i datum
Zadar, Hrvatska, 04.10.2017. - 07.10.2017

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
implant, bone cement, PMMA, roughness, morphology

Sažetak
This paper examines how implant surface roughness affects the implant-bone tissue interface. Firstly, the principles of bringing bone tissue in contact with inner surfaces in an implant-bone system are described and based on the current state in the field of research, an overview of the advantages and the disadvantages is given. Surface roughness (recognized as a relevant factor in this context) was analyzed in this study. The modification of the surface roughness parameters of the Ti6Al4V titanium alloy samples resulted from chemical etching. The etching process was carried out using Kroll's solution and nitric acid, varying exposure times. The recorded surface roughness parameter modifications were related to the morphological changes observed on the surface samples by means of scanning electron microscopy. Finally, filling out of the samples'surface defects with bone cement was analysed by means of optical microscopy, and the strength of the resulting interfaces was determined by static tensile tests.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo, Interdisciplinarne tehničke znanosti, Biotehnologija



POVEZANOST RADA


Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb

Profili:

Avatar Url Ivan Kumić (autor)


Citiraj ovu publikaciju:

Smolčić, Juraj; Stepić, Antonio; Kumić, Ivan
Implant's surface morphology and roughness influence on bonding with bone cement // MTECH INTERNATIONAL CONFERENCE ON MATERIALS
Zadar, Hrvatska, 2017. str. 341-350 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Smolčić, J., Stepić, A. & Kumić, I. (2017) Implant's surface morphology and roughness influence on bonding with bone cement. U: MTECH INTERNATIONAL CONFERENCE ON MATERIALS.
@article{article, author = {Smol\v{c}i\'{c}, Juraj and Stepi\'{c}, Antonio and Kumi\'{c}, Ivan}, year = {2017}, pages = {341-350}, keywords = {implant, bone cement, PMMA, roughness, morphology}, title = {Implant's surface morphology and roughness influence on bonding with bone cement}, keyword = {implant, bone cement, PMMA, roughness, morphology}, publisherplace = {Zadar, Hrvatska} }
@article{article, author = {Smol\v{c}i\'{c}, Juraj and Stepi\'{c}, Antonio and Kumi\'{c}, Ivan}, year = {2017}, pages = {341-350}, keywords = {implant, bone cement, PMMA, roughness, morphology}, title = {Implant's surface morphology and roughness influence on bonding with bone cement}, keyword = {implant, bone cement, PMMA, roughness, morphology}, publisherplace = {Zadar, Hrvatska} }