Pregled bibliografske jedinice broj: 944139
Three Phase Transformer Grounding Influence Analysis on Inrush Current
Three Phase Transformer Grounding Influence Analysis on Inrush Current // DIGEST BOOK OF THE SEVENTH SYMPOSIUM ON APPLIED ELECTROMAGNETICS SAEM'18 / Seme, Sebastijan ; Hadžiselimović, Miralem ; Štumberger, Bojan (ur.).
Maribor: Univerzitetna založba Univerze v Mariboru, 2018. str. 25-26 doi:10.18690/978-961-286-171-1 (predavanje, podatak o recenziji nije dostupan, prošireni sažetak, znanstveni)
CROSBI ID: 944139 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Three Phase Transformer Grounding Influence Analysis on Inrush Current
(Three phase transformer grounding influence analysis on inrush current)
Autori
Špoljarić, Željko ; Jerković Štil, Vedrana ; Hederić, Željko
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, prošireni sažetak, znanstveni
Izvornik
DIGEST BOOK OF THE SEVENTH SYMPOSIUM ON APPLIED ELECTROMAGNETICS SAEM'18
/ Seme, Sebastijan ; Hadžiselimović, Miralem ; Štumberger, Bojan - Maribor : Univerzitetna založba Univerze v Mariboru, 2018, 25-26
ISBN
978-961-286-171-1
Skup
7th International Symposium on Applied Electromagnetics (SAEM 18)
Mjesto i datum
Podčetrtek, Slovenija, 17.06.2018. - 20.06.2018
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Podatak o recenziji nije dostupan
Ključne riječi
Three Phase Transformer ; Inrush Current ; Grounding Influence
(three phase transformer ; inrush current ; grounding influence)
Sažetak
The main object of research is analysis of grounding influence of three phase transformer on inrush current which occurs during switching of unloaded transformer on to electric grid. Inrush current analysis covers the area of transition behaviour of power transformers. For this purpose, a simulation model shown in Fig. 1 is developed [1]. The model can be used for determination of inrush current amplitude, time of duration and Fourier higher harmonics analysis of power transformers with different voltage level, power and connection. The main idea of model possibilities is given in [2]. Basics inrush current analysis, calculation and measurement is given in [3, 4]. Problems which inrush current can cause is given in [5]. As mentioned, type of transformer grounding can have influence on inrush current amplitude, duration, higher harmonic content and THD factor (Total Harmonic Disorder). Results of analysis on example of one power transformer (250 kVA, 20/0, 42 kV, Yz5) for cases of direct grounding, grounding through various resistances and isolated grounding will be shown.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika