Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 942326

Total Ambient Dose Equivalent Neutron Buildup Factor Calculation Using TART


Dučkić, Paulina; Trontl, Krešimir; Pevec, Dubravko; Matijević, Mario
Total Ambient Dose Equivalent Neutron Buildup Factor Calculation Using TART // 12th International Conference of the Croatian Nuclear Society Conference Proceedings / Vrbanić, Ivan ; Šadek, Siniša ; Bašić, Ivica (ur.).
Zagreb: Hrvatsko nuklearno društvo, 2018. str. 149-1 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 942326 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Total Ambient Dose Equivalent Neutron Buildup Factor Calculation Using TART

Autori
Dučkić, Paulina ; Trontl, Krešimir ; Pevec, Dubravko ; Matijević, Mario

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
12th International Conference of the Croatian Nuclear Society Conference Proceedings / Vrbanić, Ivan ; Šadek, Siniša ; Bašić, Ivica - Zagreb : Hrvatsko nuklearno društvo, 2018, 149-1

ISBN
978-953-48100-1-9

Skup
12th International Conference of the Croatian Nuclear Society

Mjesto i datum
Zadar, Hrvatska, 03.06.2018. - 06.06.2018

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
neutron buildup factor, transmission factors, ambient dose equivalent, TART, shielding

Sažetak
In this work a Monte Carlo transport code named TART is engaged for total neutron buildup factors determination for NBS04 concrete type. The first step to model the total neutron buildup factors is to conduct a validation process of the TART code by calculating transmission factors for both neutrons and secondary photons. The transmission factors are then used for total ambient dose equivalent estimation. The direct component is calculated manually by using the exponential law, with the cross sections obtained from MCNP6. Finally, total ambient dose equivalent neutron buildup factor is calculated as the ratio of the total ambient dose equivalent and the direct component. The results are compared with the MCNP6 results. Obtained buildup factors are then embedded in a point kernel code named QAD- CGGP. A test case is modeled in TART, MCNP6 and QAD- CGGP and the results of the three codes are compared.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb


Citiraj ovu publikaciju:

Dučkić, Paulina; Trontl, Krešimir; Pevec, Dubravko; Matijević, Mario
Total Ambient Dose Equivalent Neutron Buildup Factor Calculation Using TART // 12th International Conference of the Croatian Nuclear Society Conference Proceedings / Vrbanić, Ivan ; Šadek, Siniša ; Bašić, Ivica (ur.).
Zagreb: Hrvatsko nuklearno društvo, 2018. str. 149-1 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Dučkić, P., Trontl, K., Pevec, D. & Matijević, M. (2018) Total Ambient Dose Equivalent Neutron Buildup Factor Calculation Using TART. U: Vrbanić, I., Šadek, S. & Bašić, I. (ur.)12th International Conference of the Croatian Nuclear Society Conference Proceedings.
@article{article, author = {Du\v{c}ki\'{c}, Paulina and Trontl, Kre\v{s}imir and Pevec, Dubravko and Matijevi\'{c}, Mario}, year = {2018}, pages = {149-1-149-14}, keywords = {neutron buildup factor, transmission factors, ambient dose equivalent, TART, shielding}, isbn = {978-953-48100-1-9}, title = {Total Ambient Dose Equivalent Neutron Buildup Factor Calculation Using TART}, keyword = {neutron buildup factor, transmission factors, ambient dose equivalent, TART, shielding}, publisher = {Hrvatsko nuklearno dru\v{s}tvo}, publisherplace = {Zadar, Hrvatska} }
@article{article, author = {Du\v{c}ki\'{c}, Paulina and Trontl, Kre\v{s}imir and Pevec, Dubravko and Matijevi\'{c}, Mario}, year = {2018}, pages = {149-1-149-14}, keywords = {neutron buildup factor, transmission factors, ambient dose equivalent, TART, shielding}, isbn = {978-953-48100-1-9}, title = {Total Ambient Dose Equivalent Neutron Buildup Factor Calculation Using TART}, keyword = {neutron buildup factor, transmission factors, ambient dose equivalent, TART, shielding}, publisher = {Hrvatsko nuklearno dru\v{s}tvo}, publisherplace = {Zadar, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font