Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 937611

Comparison of finned tube and plate-finned heat exchangers in waste heat recovery


Holik, Mario; Živić, Marija; Virag, Zdravko; Barac, Antun
Comparison of finned tube and plate-finned heat exchangers in waste heat recovery // Transactions of FAMENA, 42 (2018), SI-1; 1-12 doi:10.21278/TOF.42Si101 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 937611 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparison of finned tube and plate-finned heat exchangers in waste heat recovery

Autori
Holik, Mario ; Živić, Marija ; Virag, Zdravko ; Barac, Antun

Izvornik
Transactions of FAMENA (1333-1124) 42 (2018), SI-1; 1-12

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
heat exchangers ; heat transfer ; minimization of heat exchanger volume ; Pareto frontier

Sažetak
The use of waste heat recovery devices on mobile units (trucks and ships) is usually limited by the available space and the application of compact heat exchangers is recom¬mended for such purposes. The performance of the heat exchanger is defined by the optimized Rankine cycle (to achieve maximum power) and it depends on the mass flow and temperature of the flue gases and selection of the working fluid in Rankine cycle. An example of selection of the preheater performance (in case of water as the working fluid) is considered here, wherein the several surface types of finned tube and plate-finned heat exchangers are used, for which there are measured data of the heat transfer coefficient and friction factor. Heat exchangers are sized according to the criteria of maximum allowed velocity of the flue gases and shapes of the heat exchanger frontal area. The sized heat exchangers were compared with respect to the heat transfer coefficient, the area of the heat exchanger surface on the finned side, the volume of the heat exchanger and the pressure drop on both sides. From the comparison of the best plate-finned and the best finned tube heat exchangers it is concluded that in the recommended range of flue gases velocity (from 4 m/s to 6 m/s) the pressure drop at the gas side are similar (in the plate-finned heat exchanger it is in the range from 53.5 to 112 Pa and in the finned tube exchanger from 53.8 to 142.8 Pa), while the plate-finned exchanger has more than 50% smaller heat transfer area, compared to the finned tube one.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb,
Strojarski fakultet, Slavonski Brod

Profili:

Avatar Url Marija Živić (autor)

Avatar Url Mario Holik (autor)

Avatar Url Antun Barac (autor)

Avatar Url Zdravko Virag (autor)

Poveznice na cjeloviti tekst rada:

doi hrcak.srce.hr

Citiraj ovu publikaciju:

Holik, Mario; Živić, Marija; Virag, Zdravko; Barac, Antun
Comparison of finned tube and plate-finned heat exchangers in waste heat recovery // Transactions of FAMENA, 42 (2018), SI-1; 1-12 doi:10.21278/TOF.42Si101 (međunarodna recenzija, članak, znanstveni)
Holik, M., Živić, M., Virag, Z. & Barac, A. (2018) Comparison of finned tube and plate-finned heat exchangers in waste heat recovery. Transactions of FAMENA, 42 (SI-1), 1-12 doi:10.21278/TOF.42Si101.
@article{article, author = {Holik, Mario and \v{Z}ivi\'{c}, Marija and Virag, Zdravko and Barac, Antun}, year = {2018}, pages = {1-12}, DOI = {10.21278/TOF.42Si101}, keywords = {heat exchangers, heat transfer, minimization of heat exchanger volume, Pareto frontier}, journal = {Transactions of FAMENA}, doi = {10.21278/TOF.42Si101}, volume = {42}, number = {SI-1}, issn = {1333-1124}, title = {Comparison of finned tube and plate-finned heat exchangers in waste heat recovery}, keyword = {heat exchangers, heat transfer, minimization of heat exchanger volume, Pareto frontier} }
@article{article, author = {Holik, Mario and \v{Z}ivi\'{c}, Marija and Virag, Zdravko and Barac, Antun}, year = {2018}, pages = {1-12}, DOI = {10.21278/TOF.42Si101}, keywords = {heat exchangers, heat transfer, minimization of heat exchanger volume, Pareto frontier}, journal = {Transactions of FAMENA}, doi = {10.21278/TOF.42Si101}, volume = {42}, number = {SI-1}, issn = {1333-1124}, title = {Comparison of finned tube and plate-finned heat exchangers in waste heat recovery}, keyword = {heat exchangers, heat transfer, minimization of heat exchanger volume, Pareto frontier} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font