Pregled bibliografske jedinice broj: 937399
Switch based on relays with low operation and release time for AC-DC transfer difference measurements
Switch based on relays with low operation and release time for AC-DC transfer difference measurements // Proceedings of First International Colloquium on Smart Grid Metrology 2018 (SMAGRIMET 2018) / Ivšić, Branimir ; Jurčević, Marko (ur.).
Zagreb: Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2018. str. 87-89 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 937399 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Switch based on relays with low operation and release time for AC-DC transfer difference measurements
Autori
Konjevod, Jure ; Hegeduš, Hrvoje ; Malarić, Roman ; Kunšt, Ivica
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of First International Colloquium on Smart Grid Metrology 2018 (SMAGRIMET 2018)
/ Ivšić, Branimir ; Jurčević, Marko - Zagreb : Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2018, 87-89
ISBN
978-953-184-234-1
Skup
First International Colloquium on Smart Grid Metrology (SmaGriMet 2018)
Mjesto i datum
Split, Hrvatska, 24.04.2018. - 27.04.2018
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
fast switching, ac-dc transfer difference measurement, thermal voltage converter, operation time of relays, release time of relays
Sažetak
A fast switching system for AC-DC transfer difference measurements is presented in this paper. The paper describes assembling process of fast switching system. The system consists of control unit and relay box, in which relays are placed. Also, whole system is developed in- house for the purpose of AC-DC transfer difference measurement. This measurement is one parameter within characterization of nine shunts (cage type design) in range from 1 mA up to 10 A. This measurement includes using thermal converters. Since, it is substantial to apply ac, dc+ and dc- voltage without interruptions. That means switching time must be smaller than thermal time constant of the thermal converters.
Izvorni jezik
Engleski
POVEZANOST RADA
Projekti:
HRZZ-IP-2014-09-8826 - Mjeriteljska infrastruktura za pametne mreže (SMAGRIMET) (Malarić, Roman, HRZZ ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb