A Circular Loop Time Constant Standard for the Determination of Phase Angle Errors of Current Shunts


Dadić, Martin; Sandelić, Monika; Hegeduš, Hrvoje; Petrović, Goran
A Circular Loop Time Constant Standard for the Determination of Phase Angle Errors of Current Shunts // Proceedings of First International Colloquium on Smart Grid Metrology 2018 (SMAGRIMET 2018) / Ivšić, Branimir ; Jurčević, Marko (ur.).
Zagreb: Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2018. str. 64-68 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 937120 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
A Circular Loop Time Constant Standard for the Determination of Phase Angle Errors of Current Shunts

Autori
Dadić, Martin ; Sandelić, Monika ; Hegeduš, Hrvoje ; Petrović, Goran

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of First International Colloquium on Smart Grid Metrology 2018 (SMAGRIMET 2018) / Ivšić, Branimir ; Jurčević, Marko - Zagreb : Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2018, 64-68

ISBN
978-953-184-234-1

Skup
First International Colloquium on Smart Grid Metrology (SmaGriMet 2018)

Mjesto i datum
Split, Hrvatska, 24.04.2018. - 27.04.2018

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
time constant standard, circular loop, phase angle measurment

Sažetak
The paper describes a simple time constant standard, developed for the phase angle measurement of the precision current shunts. Its design is based on a single circular loop, placed in an air thermostat.

Izvorni jezik
Engleski



POVEZANOST RADA


Projekti:
HRZZ-IP-2014-09-8826 - Mjeriteljska infrastruktura za pametne mreže (SMAGRIMET) (Malarić, Roman, HRZZ ) ( CroRIS)

Profili:

Avatar Url Hrvoje Hegeduš (autor)

Avatar Url Goran Petrović (autor)

Avatar Url Martin Dadić (autor)


Citiraj ovu publikaciju:

Dadić, Martin; Sandelić, Monika; Hegeduš, Hrvoje; Petrović, Goran
A Circular Loop Time Constant Standard for the Determination of Phase Angle Errors of Current Shunts // Proceedings of First International Colloquium on Smart Grid Metrology 2018 (SMAGRIMET 2018) / Ivšić, Branimir ; Jurčević, Marko (ur.).
Zagreb: Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2018. str. 64-68 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Dadić, M., Sandelić, M., Hegeduš, H. & Petrović, G. (2018) A Circular Loop Time Constant Standard for the Determination of Phase Angle Errors of Current Shunts. U: Ivšić, B. & Jurčević, M. (ur.)Proceedings of First International Colloquium on Smart Grid Metrology 2018 (SMAGRIMET 2018).
@article{article, author = {Dadi\'{c}, Martin and Sandeli\'{c}, Monika and Hegedu\v{s}, Hrvoje and Petrovi\'{c}, Goran}, year = {2018}, pages = {64-68}, keywords = {time constant standard, circular loop, phase angle measurment}, isbn = {978-953-184-234-1}, title = {A Circular Loop Time Constant Standard for the Determination of Phase Angle Errors of Current Shunts}, keyword = {time constant standard, circular loop, phase angle measurment}, publisher = {Fakultet elektrotehnike i ra\v{c}unarstva Sveu\v{c}ili\v{s}ta u Zagrebu}, publisherplace = {Split, Hrvatska} }
@article{article, author = {Dadi\'{c}, Martin and Sandeli\'{c}, Monika and Hegedu\v{s}, Hrvoje and Petrovi\'{c}, Goran}, year = {2018}, pages = {64-68}, keywords = {time constant standard, circular loop, phase angle measurment}, isbn = {978-953-184-234-1}, title = {A Circular Loop Time Constant Standard for the Determination of Phase Angle Errors of Current Shunts}, keyword = {time constant standard, circular loop, phase angle measurment}, publisher = {Fakultet elektrotehnike i ra\v{c}unarstva Sveu\v{c}ili\v{s}ta u Zagrebu}, publisherplace = {Split, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font