Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 9331

Proton micro-PIXE control of standard reference materials for PIXE environmental application


Tadić, Tonči; Jakšić, Milko; Bogdanović, Ivančica; Fazinić, Stjepko; Dujmić, Denis
Proton micro-PIXE control of standard reference materials for PIXE environmental application // Proceedings, IAEA-SM-344/54 / IAEA (ur.).
Hyderābād, Indija: IAEA, Vienna, 1997. str. 251-264 (predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 9331 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Proton micro-PIXE control of standard reference materials for PIXE environmental application

Autori
Tadić, Tonči ; Jakšić, Milko ; Bogdanović, Ivančica ; Fazinić, Stjepko ; Dujmić, Denis

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings, IAEA-SM-344/54 / IAEA - : IAEA, Vienna, 1997, 251-264

Skup
International Symposium on Harmonization of Helth Related Environmental Measurements using Nuclear and Isotopi

Mjesto i datum
Hyderābād, Indija, 04.11.1996. - 07.11.1996

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Nije recenziran

Ključne riječi
reference material; PIXE; proton microprobe

Sažetak
In quality control processes, certified standard reference materials (SRMs) are of great importance. They are necssary for checking the effectiveness and precision of analytical techniques, as well as for comparing results between different laboratories. Owing to the relatively low sample mass analysed by the particle induced X ray emission (PIXE) method, sample inhomogeneity has to be considered in the PIXE analytical technique. The trace element distribution and elemental composition of SRMs must be constant in all portions of the SRM and as close to the certified values as possible, even in the smallest amount of the sample used. In order to study these effects, several powder SRMs and the candidate SRMs used in environmental and biological applications of the PIXE analytical method have been tested for reliability at the microgram scale. Inhomogeneity in each of these samples has been tested in a series of micro-PIXE measurements, using a focused ion beam from the Zagreb proton micro-probe facility. The concentrations of the trace elements in the SRMs should approach the broad beam PIXE values by increasing the scan size. At the same time, the inhomogeneities observed in areal distributions of trace elements in the SRM sample can be related to the scattering of the elemental concentration around the mean value with the increasing of scan size. That is, the elements that have less homogeneous areal distributions, as observed by the microprobe, are found to have more scattered elemental concentrations than ones that have homogenous areal distribution

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Projekti:
00980206

Ustanove:
Institut "Ruđer Bošković", Zagreb


Citiraj ovu publikaciju:

Tadić, Tonči; Jakšić, Milko; Bogdanović, Ivančica; Fazinić, Stjepko; Dujmić, Denis
Proton micro-PIXE control of standard reference materials for PIXE environmental application // Proceedings, IAEA-SM-344/54 / IAEA (ur.).
Hyderābād, Indija: IAEA, Vienna, 1997. str. 251-264 (predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)
Tadić, T., Jakšić, M., Bogdanović, I., Fazinić, S. & Dujmić, D. (1997) Proton micro-PIXE control of standard reference materials for PIXE environmental application. U: IAEA (ur.)Proceedings, IAEA-SM-344/54.
@article{article, author = {Tadi\'{c}, Ton\v{c}i and Jak\v{s}i\'{c}, Milko and Bogdanovi\'{c}, Ivan\v{c}ica and Fazini\'{c}, Stjepko and Dujmi\'{c}, Denis}, year = {1997}, pages = {251-264}, keywords = {reference material, PIXE, proton microprobe}, title = {Proton micro-PIXE control of standard reference materials for PIXE environmental application}, keyword = {reference material, PIXE, proton microprobe}, publisher = {IAEA, Vienna}, publisherplace = {Hyder\={a}b\={a}d, Indija} }
@article{article, author = {Tadi\'{c}, Ton\v{c}i and Jak\v{s}i\'{c}, Milko and Bogdanovi\'{c}, Ivan\v{c}ica and Fazini\'{c}, Stjepko and Dujmi\'{c}, Denis}, year = {1997}, pages = {251-264}, keywords = {reference material, PIXE, proton microprobe}, title = {Proton micro-PIXE control of standard reference materials for PIXE environmental application}, keyword = {reference material, PIXE, proton microprobe}, publisher = {IAEA, Vienna}, publisherplace = {Hyder\={a}b\={a}d, Indija} }




Contrast
Increase Font
Decrease Font
Dyslexic Font