Pregled bibliografske jedinice broj: 925060
Analysis of Spent Fuel Pool Loss of Coolant Inventory Accident Progression
Analysis of Spent Fuel Pool Loss of Coolant Inventory Accident Progression // Energija : časopis Hrvatske elektroprivrede, 66 (2017), S.I.; 99-107 (podatak o recenziji nije dostupan, članak, znanstveni)
CROSBI ID: 925060 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Analysis of Spent Fuel Pool Loss of Coolant Inventory Accident Progression
Autori
Đaković, Josip ; Grgić, Davor
Izvornik
Energija : časopis Hrvatske elektroprivrede (0013-7448) 66
(2017), S.I.;
99-107
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Spent Fuel Pool ; Loss of Coolant accident ; fuel heatup, cladding oxidation, decay heat, NPP Krško
Sažetak
The Spent Fuel Pool (SFP) in a nuclear power plant is a robust structure designed to withstand large seismic loads. After the terrorist attacks on September 11 and the accident in the Fukushima nuclear power plant, special attention was focused on safety assessments and taking measures to mitigate possible accidents related to the spent fuel pool. This paper will provide an insight into spent fuel pool loss of coolant phenomenology and consequence mitigation strategies. Model of NPP Krško SFP was presented in MELCOR code which has been used as a case-study for evaluating accident propagation. The calculations were carried out using the latest version of MELCOR code which was updated for the analysis of severe accidents in nuclear spent fuel pools.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb