Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 924164

Patient safety is not compromised by excluding microscopic examination of negative urine dipstick


Miler, Marijana; Nikolac, Nora
Patient safety is not compromised by excluding microscopic examination of negative urine dipstick // Annals of clinical biochemistry, 55 (2018), 1; 77-83 doi:10.1177/0004563216687589 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 924164 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Patient safety is not compromised by excluding microscopic examination of negative urine dipstick

Autori
Miler, Marijana ; Nikolac, Nora

Izvornik
Annals of clinical biochemistry (0004-5632) 55 (2018), 1; 77-83

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
laboratory optimization ; patient safety ; risk analysis ; urinalysis

Sažetak
Microscopic examination of samples with negative dipstick results is not necessary. The aims of this study were to: (i) assess the risk of excluding urine sediment examination with negative dipstick results and (ii) calculate time savings by introducing this process. The risk analysis was done for samples with negative urine dipstick and positive sediment findings. Possible missed elements in sediment were defined as 21 errors. Time saving was calculated as average time for preparation and examination sediments. Data were presented as counts and percentages. Out of 2997 samples, negative dipstick results were reported for 926 (30.6%) samples, out of which, microscopic examinations were positive for 527 (17.6%) samples. 18/21 errors were detected, with missing <5 squamous epithelial cells (SQEC) and bacteria 1+ as the most frequent ones (22.7% and 22.4%, respectively). Errors with the intermediate risk for patients were missing to report: ≥5 SQEC, ≥5 transitional epithelial cells, ≥10 hyaline casts (11.9%, 0.21%, 0.32%, respectively). Errors associated with high risk were not detected. Estimated total time saving is more than 25 h/month. Microscopic examination of urine samples with negative dipstick results can be excluded without risk for patients and can result with considerable time savings.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
KBC "Sestre Milosrdnice"

Profili:

Avatar Url Nora Nikolac (autor)

Avatar Url Marijana Miler (autor)

Poveznice na cjeloviti tekst rada:

doi journals.sagepub.com journals.sagepub.com doi.org

Citiraj ovu publikaciju:

Miler, Marijana; Nikolac, Nora
Patient safety is not compromised by excluding microscopic examination of negative urine dipstick // Annals of clinical biochemistry, 55 (2018), 1; 77-83 doi:10.1177/0004563216687589 (međunarodna recenzija, članak, znanstveni)
Miler, M. & Nikolac, N. (2018) Patient safety is not compromised by excluding microscopic examination of negative urine dipstick. Annals of clinical biochemistry, 55 (1), 77-83 doi:10.1177/0004563216687589.
@article{article, author = {Miler, Marijana and Nikolac, Nora}, year = {2018}, pages = {77-83}, DOI = {10.1177/0004563216687589}, keywords = {laboratory optimization, patient safety, risk analysis, urinalysis}, journal = {Annals of clinical biochemistry}, doi = {10.1177/0004563216687589}, volume = {55}, number = {1}, issn = {0004-5632}, title = {Patient safety is not compromised by excluding microscopic examination of negative urine dipstick}, keyword = {laboratory optimization, patient safety, risk analysis, urinalysis} }
@article{article, author = {Miler, Marijana and Nikolac, Nora}, year = {2018}, pages = {77-83}, DOI = {10.1177/0004563216687589}, keywords = {laboratory optimization, patient safety, risk analysis, urinalysis}, journal = {Annals of clinical biochemistry}, doi = {10.1177/0004563216687589}, volume = {55}, number = {1}, issn = {0004-5632}, title = {Patient safety is not compromised by excluding microscopic examination of negative urine dipstick}, keyword = {laboratory optimization, patient safety, risk analysis, urinalysis} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font