Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 917337

Computational Artifacts of the In Situ Electric Field in Anatomical Models Exposed to Low-Frequency Magnetic Field


Gomez-Tames, Jose; Laakso, Ilkka; Haba, Yuto; Hirata, Akimasa; Poljak, Dragan; Yamazaki, Kenichi
Computational Artifacts of the In Situ Electric Field in Anatomical Models Exposed to Low-Frequency Magnetic Field // IEEE transactions on electromagnetic compatibility, 60 (2018), 3; 589-597 doi:10.1109/TEMC.2017.2748219 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 917337 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Computational Artifacts of the In Situ Electric Field in Anatomical Models Exposed to Low-Frequency Magnetic Field

Autori
Gomez-Tames, Jose ; Laakso, Ilkka ; Haba, Yuto ; Hirata, Akimasa ; Poljak, Dragan ; Yamazaki, Kenichi

Izvornik
IEEE transactions on electromagnetic compatibility (0018-9375) 60 (2018), 3; 589-597

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Biological effects of electromagnetic field ; blood flow measurement ; dosimetry ; simulation ; standardization

Sažetak
An in situ (internal) electric field is used as a dosimetric quantity for human protection from low-frequency electromagnetic fields (lower than 5 MHz) under international safety standard/ ; guidelines. The IEEE standard uses a homogenous elliptical cross section to derive external field strength corresponding to an in situ field strength, while the International Committee on Non-Ionizing Radiation Protection (ICNIRP) guidelines use anatomical models to relate them. In the latter, “the 99th percentile value of the in situ electric field averaged over the cube of its side length of 2 mm” is used to represent the maximum in situ electric field. This metric was introduced to suppress computational artifacts that are inherent when using voxelized anatomical models, in which curved boundaries are discretized with a stair-casing approximation. To suppress the error, a few schemes have been proposed for treating the computational artifacts. In this study, the various schemes to suppress the artifacts are reviewed. Subsequently, a postprocessing method for determining the appropriate maximum in situ field strength is proposed. The performance of the proposed scheme is first verified by comparison with an analytical solution in a multilayered sphere. The method is then applied for different exposure scenarios in anatomically realistic human models where the volume under computation is also considered.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split

Profili:

Avatar Url Dragan Poljak (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada doi ieeexplore.ieee.org

Citiraj ovu publikaciju:

Gomez-Tames, Jose; Laakso, Ilkka; Haba, Yuto; Hirata, Akimasa; Poljak, Dragan; Yamazaki, Kenichi
Computational Artifacts of the In Situ Electric Field in Anatomical Models Exposed to Low-Frequency Magnetic Field // IEEE transactions on electromagnetic compatibility, 60 (2018), 3; 589-597 doi:10.1109/TEMC.2017.2748219 (međunarodna recenzija, članak, znanstveni)
Gomez-Tames, J., Laakso, I., Haba, Y., Hirata, A., Poljak, D. & Yamazaki, K. (2018) Computational Artifacts of the In Situ Electric Field in Anatomical Models Exposed to Low-Frequency Magnetic Field. IEEE transactions on electromagnetic compatibility, 60 (3), 589-597 doi:10.1109/TEMC.2017.2748219.
@article{article, author = {Gomez-Tames, Jose and Laakso, Ilkka and Haba, Yuto and Hirata, Akimasa and Poljak, Dragan and Yamazaki, Kenichi}, year = {2018}, pages = {589-597}, DOI = {10.1109/TEMC.2017.2748219}, keywords = {Biological effects of electromagnetic field, blood flow measurement, dosimetry, simulation, standardization}, journal = {IEEE transactions on electromagnetic compatibility}, doi = {10.1109/TEMC.2017.2748219}, volume = {60}, number = {3}, issn = {0018-9375}, title = {Computational Artifacts of the In Situ Electric Field in Anatomical Models Exposed to Low-Frequency Magnetic Field}, keyword = {Biological effects of electromagnetic field, blood flow measurement, dosimetry, simulation, standardization} }
@article{article, author = {Gomez-Tames, Jose and Laakso, Ilkka and Haba, Yuto and Hirata, Akimasa and Poljak, Dragan and Yamazaki, Kenichi}, year = {2018}, pages = {589-597}, DOI = {10.1109/TEMC.2017.2748219}, keywords = {Biological effects of electromagnetic field, blood flow measurement, dosimetry, simulation, standardization}, journal = {IEEE transactions on electromagnetic compatibility}, doi = {10.1109/TEMC.2017.2748219}, volume = {60}, number = {3}, issn = {0018-9375}, title = {Computational Artifacts of the In Situ Electric Field in Anatomical Models Exposed to Low-Frequency Magnetic Field}, keyword = {Biological effects of electromagnetic field, blood flow measurement, dosimetry, simulation, standardization} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font