Pregled bibliografske jedinice broj: 912006
Kinetic Spectrophotometric Determination of N-Acetyl-L-cysteine Ethyl Ester (NACET) Generating Chromogenic Copper(I)Ln Complexes with Different Ligands
Kinetic Spectrophotometric Determination of N-Acetyl-L-cysteine Ethyl Ester (NACET) Generating Chromogenic Copper(I)Ln Complexes with Different Ligands // Croatica chemica acta, 90 (2017), 2; 263-271 doi:10.5562/cca3135 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 912006 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Kinetic Spectrophotometric Determination of N-Acetyl-L-cysteine Ethyl Ester (NACET) Generating Chromogenic Copper(I)Ln Complexes with Different Ligands
Autori
Kukoc-Modun, Lea ; Tsikas, Dimitrios ; Kraljević, Tomislav ; Biocic, Maja ; Radić, Njegomir
Izvornik
Croatica chemica acta (0011-1643) 90
(2017), 2;
263-271
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
N-acetyl-L-cysteine ethyl ester ; kinetic spectrophotometry ; neocuproine ; bicinchoninic acid ; bathocuproine disulfonic acid
Sažetak
Three simple, sensitive and robust kinetic spectrophotometric methods for the determination of a novel lipophilic thiol compound, N-acetyl-L-cysteine ethyl ester (NACET), have been developed and validated. The methods are based on the reduction of Cu(II)-ligand complex to Cu(I)-ligand complex with the analyte. Studied ligands were neocuproine, bicinchoninic acid (BCA) and bathocuproine disulfonic acid (BCS). The development of chromogenic complexes was followed using kinetic setup with spectrophotometric detection at 458, 562 and 483 nm for the reactions of NACET with neocuproine, BCA and BCS, respectively. The calculated reaction orders with respect to NACET concentration were found to be 1.07, 1.01, 1.07, respectively, thus confirming a first order of reaction. The initial rate and fixed time methods were utilized for constructing calibration curves. Assays limits of detection were 1.4 × 10–7, 3.2 × 10−7 and 6.0 × 10−8 mol L–1, respectively. The analytical performance of the methods, in terms of accuracy and precision, was established.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Projekti:
MZOS-011-0000000-3217 - Određivanje tiola primjenom potenciometrijskih senzora i spektroskopije (Radić, Njegomir, MZOS ) ( CroRIS)
Ustanove:
Kemijsko-tehnološki fakultet, Split
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus