Pregled bibliografske jedinice broj: 911704
Photometric latex test for rheumatoid factors in patients with rheumatoid arthritis. I. correlation with other serologic tests
Photometric latex test for rheumatoid factors in patients with rheumatoid arthritis. I. correlation with other serologic tests // Zeitschrift für Rheumatologie, 37 (1978), 3/4; 93-104 (recenziran, članak, znanstveni)
CROSBI ID: 911704 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Photometric latex test for rheumatoid factors in patients with rheumatoid arthritis. I. correlation with other serologic tests
Autori
Deželić, Nada ; Zergollern, Vesna ; Deželić, Gjuro ; Dürrigl, Theodor ; Jurak, Herman ; Vitauš, Marijan ; Androić, Stjepan
Izvornik
Zeitschrift für Rheumatologie (0340-1855) 37
(1978), 3/4;
93-104
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Photometric latex test ; rheumatoid factors ; rheumatoid arthritis ; correlation with serologic tests
Sažetak
The photometric latex test (PLT) for the detection of rheumatoid factors (RF) has been correlated with the sensitized sheep cell test (SSC) and the latex slide test (LST). A total of 377 sera from patients with rheumatoid arthritis (RA) and 120 sera from control subjects were examined. When the PLT was carried out on the native sera at a lower buffer ionic strength (0.05 M), agglutination was noted in over 99 % of cases, indicating interaction of complement with human immunoglobulin bound to the latex particle surface. Although thermal inactivation eliminated most of the complement agglutination, an increase in ionic strength (0.5 M) was found to be essential for measuring only RF agglutination. The serologic data were analysed statistically by computer. A highly significant correlation was found between all serologic tests and RA sera, but there was no such correlation with the control sera. The specificity of all tests was generally over 90 % and did not vary significantly, but the sensitivity varied from 52.0 % to 71.1 %, confirming that about one-third of all RA patients are seronegative. The tests were analysed for their total diagnostic capability. The PLT with native sera at higher ionic strength proved to be the most sensitive, but with thermally inactivated sera it had a better diagnostic capacity. The SSC test appeared to be less sensitive and of lower diagnostic validity. Rapid LST tests were clearly inferior to PLT tests. The PLT can be used as a reliable and straightforward serologic method of diagnosis in RA, especially when carried out at a higher ionic strength and with thermally inactivated sera. It should be given preference over other serologic tests for RF and could well become standard practice in rheumatologic serology as a substitute for the SSC test.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Scopus
- MEDLINE
Uključenost u ostale bibliografske baze podataka::
- MEDLINE