Pregled bibliografske jedinice broj: 908072
Safe and simple procedure to restrain rats for blood sampling from tail vein
Safe and simple procedure to restrain rats for blood sampling from tail vein // SLOVENIAN VETERINARY RESEARCH Supplement 18 3rd Congress of the SLAS and 1st joint SLAS - CroLASA meeting. U: Slovenian veterinary research 2017(suppl 18) / Simona Kranjc, Gregor Majdič (ur.).
Ljubljana, 2017. str. 53-53 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 908072 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Safe and simple procedure to restrain rats for blood
sampling from tail vein
Autori
Marolt Banek, Iva ; Šućur, Alan ; Kelava, Tomislav ; Crljen, Vladiana
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
SLOVENIAN VETERINARY RESEARCH Supplement 18 3rd Congress of the SLAS and 1st joint SLAS - CroLASA meeting. U: Slovenian veterinary research 2017(suppl 18)
/ Simona Kranjc, Gregor Majdič - Ljubljana, 2017, 53-53
Skup
3rd Congress of the SLAS and 1st joint SLAS - CroLASA meeting
Mjesto i datum
Ljubljana, Slovenija, 15.06.2017. - 16.06.2017
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
restraint device ; tail vein blood collection in rat
Sažetak
Everyday laboratory practice and teaching procedures include handling laboratory rats in order to collect blood samples from the tail vein. For that purpose, a restraining device is needed. It is generally accepted to restrain the rat either by wrapping it into the towel or by using one plastic cylinder that can be adapted to animal size. Exposing the rat to such a procedure is potentially stressful and detrimental to obtaining a proper sample. Also, while trying to place the rat in the restraining device, the animal might resist the procedure. Here we propose a simple, effective and harmless way to restrain the rat. Two plastic cylinders are needed. Their diameter is such that the smaller cylinder can be placed within the bigger one. As smaller cylinder we used plastic bottle. The cover and the bottom of the bottle were removed, leaving a cylinder that is narrow on one end. The cylinder with bigger diameter has a cover on each end. On one end of a bigger cylinder, the cover has only one hole, which is suitable to place the rat's tail. On the other end of the same cylinder, the cover has several smaller holes to enable a free flow of air for breathing. Both covers are firmly attached to the outer cylinder. Once the rat is placed within the cylinders, it cannot move and stays immobile within a cylinder of smaller diameter. This way, the tail is freely accessible, making blood sampling from the tail vein fast and easy. Using two such cylinders can make blood sampling from the tail vein safe and simple. The need for touching the rat is minimal, since both cylinders can be placed into the cage so that the rat can freely enter the smaller cylinder while moving around the cage. Advantage of such a device is low cost, ease of use and minimal physical contact with the rat when the animal is already inside the smaller cylinder. Using such a device reduces potential stress in the laboratory rat caused by blood sampling and eliminates need for anaesthesia.
Izvorni jezik
Engleski
Znanstvena područja
Temeljne medicinske znanosti
POVEZANOST RADA
Ustanove:
Stomatološki fakultet, Zagreb,
Medicinski fakultet, Zagreb
Profili:
Vladiana Crljen
(autor)
Alan Šućur
(autor)
Iva Marolt Banek
(autor)
Tomislav Kelava
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus