Pregled bibliografske jedinice broj: 900532
Distance Protection and Automatic Reclosing on 400 kV Transmission Line with Classic and Compact Towers
Distance Protection and Automatic Reclosing on 400 kV Transmission Line with Classic and Compact Towers // Proceedings of International Conference on Smart Systems and Technologies 2017 (SST 2017) / Drago Žagar, Goran Martinović, Snježana Rimac Drlje, Kruno Miličević (ur.).
Osijek: Fakultet elektrotehnike, računarstva i informacijskih tehnologija Sveučilišta Josipa Jurja Strossmayera u Osijeku, 2017. str. 91-97 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 900532 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Distance Protection and Automatic Reclosing on 400 kV Transmission Line with Classic and Compact Towers
Autori
Alibašić, Emir ; Stojkov, Marinko ; Nikolovski, Srete
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of International Conference on Smart Systems and Technologies 2017 (SST 2017)
/ Drago Žagar, Goran Martinović, Snježana Rimac Drlje, Kruno Miličević - Osijek : Fakultet elektrotehnike, računarstva i informacijskih tehnologija Sveučilišta Josipa Jurja Strossmayera u Osijeku, 2017, 91-97
ISBN
978-1-5386-3776-0
Skup
International Conference on Smart Systems and Technologies 2017 (SST 2017)
Mjesto i datum
Osijek, Hrvatska, 18.10.2017. - 20.10.2017
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Transmission line ; compacting ; ground fault ; distance protection
Sažetak
The paper presents an example of modeling highvoltage line with classical columns and pillars compacted with the same lines and testing out the model in the programming tool DIgSILENT with actual measured data for Single Line to Ground Fault with the use of ARs. The parameters of the classical and compacted 400 kV transmission line are entered into the model in the example of 400 kV line Tuzla 4 – Višegrad, and Single Line to Ground Fault was simulated and compared with the actual measured data. Afterwards, lines with classical columns and pillars compacted with the lines were compared and assessed if a readjustment of distance protection on the line is necessary. The SIEMENS numerical distance relay 7SA was used.