Pregled bibliografske jedinice broj: 900258
Late Bronchus Perforation due to Spinal Implant Compression : case report
Late Bronchus Perforation due to Spinal Implant Compression : case report // Journal of Anesthesia & Critical Care, 6 (2016), 5; 1-4 doi:10.15406/jaccoa.2016.06.00241 (recenziran, članak, stručni)
CROSBI ID: 900258 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Late Bronchus Perforation due to Spinal Implant Compression : case report
Autori
Sokolović, Irena ; Slobodnjak, Zoran ; Mažuranić, Ivica
Izvornik
Journal of Anesthesia & Critical Care (2373-6437) 6
(2016), 5;
1-4
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, stručni
Ključne riječi
Foreign body ; Lobectomy ; Thoracic scoliosis ; VDS instrumentation
Sažetak
We report a rare case of perforation of the intermediate bronchus by a loosened osteosynthetic implant, 8 years after the patient had undergone surgery for right thoracic scoliosis with the VDS instrumentation. Due to chronic lung inflammatory alteration caused by bronchial obstruction, lower bi-lobectomy was performed. We believe that spinal growth and progression of idiopathic scoliosis can lead to implant failure, while the variance in intrathoracic topographic relations and respiratory excursion facilitate it's penetration into the bronchus. In order to impede foreign body perforation of mediastinal structures and to reduce its complications, preventive methods, along with timely diagnostics, are required. Atelectatic and chronic inflammatory alterations that compromise adequate lung ventilation could require a resection procedure.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Klinika za plućne bolesti "Jordanovac",
Klinički bolnički centar Zagreb
Poveznice na cjeloviti tekst rada:
Pristup cjelovitom tekstu rada doi
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- SCI-EXP, SSCI i/ili A&HCI