Pregled bibliografske jedinice broj: 899869
Current practice of hemodynamic monitoring with PICCO in a single surgical ICU in a university hospital ; short report
Current practice of hemodynamic monitoring with PICCO in a single surgical ICU in a university hospital ; short report // Signa Vitae, 13 (2017), S1; 61-64 (recenziran, kratko priopcenje, stručni)
CROSBI ID: 899869 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Current practice of hemodynamic monitoring with PICCO in a single surgical ICU in a university hospital ; short report
(Current practice of hemodynamic monitoring with PICCO in a single surgical ICU in a university hospital : short report)
Autori
Goranović, Tatjana ; Nesek Adam, Višnja ; Grizelj Stojčić, Elvira ; Jakšić, M. ; Jadrijević, Ante ; Karaman Ilić, Maja ; Matolić, Martina
Izvornik
Signa Vitae (1334-5605) 13
(2017), S1;
61-64
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, kratko priopcenje, stručni
Ključne riječi
hemodinamski monitoring, Jedicina intenzivnog liječenja
(hemodynamic monitoring . intensive care unit)
Sažetak
In recent years, there has been an overall trend toward using less invasive hemodynamic monitoring in surgical intensive care units. The pulse contour cardiac output monitor (PiCCO) is one of them. The aim of this study was to evaluate our practice of hemodynamic monitoring with PiCCO in the perioperative period. A retrospective descriptive analysis was performed in a single general surgical intensive care unit (ICU) run by anesthesiologists for the years 2013-2016. We collected information about patients, ICU quality parameters and monitoring equipment available in the ICU. The primary endpoint was the incidence of PiCCO use. Out of 2972 patients admitted to the general surgical ICU in a 4-year period, besides basic monitoring with electrocardiography (ECG), pulse oximetry and blood pressure monitoring, more than half of the patients received central venous catheterization (55.1%), less than the half invasive arterial catheterization (44.1 %) and only a small proportion PiCCO (0.91%). No patient received a pulmonary arterial catheter. Mortality rate was 7.47 %. The use of PiCCO in our ICU is far below reported in literature. In the majority of cases, our anesthesiologists make clinical decisions based on measurement of central venous and invasive arterial pressure.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Sveučilište J. J. Strossmayera u Osijeku,
Sveučilište Libertas
Profili:
Tatjana Goranović
(autor)
Ante Jadrijević
(autor)
Maja Karaman Ilić
(autor)
Višnja Nesek
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus