Pregled bibliografske jedinice broj: 897192
Effect of Combined Hole Configuration on Film Cooling
Effect of Combined Hole Configuration on Film Cooling // Digital Proceedings of 12th Conference on Sustainable Development of Energy, Water and Environment Systems - SDEWES / Ban, Marko et al. (ur.).
Zagreb: Fakultet strojarstva i brodogradnje Sveučilišta u Zagrebu, 2017. 0317, 12 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 897192 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Effect of Combined Hole Configuration on Film Cooling
Autori
Tian, Ke ; Wang, Jin ; Baleta, Jakov ; Yang Li ; Sundén, Bengt
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Digital Proceedings of 12th Conference on Sustainable Development of Energy, Water and Environment Systems - SDEWES
/ Ban, Marko et al. - Zagreb : Fakultet strojarstva i brodogradnje Sveučilišta u Zagrebu, 2017
Skup
12th Conference on Sustainable Development of Energy, Water and Environment Systems - SDEWES
Mjesto i datum
Dubrovnik, Hrvatska, 04.10.2017. - 08.10.2017
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Film cooling ; combined hole ; computational fluid dynamics ; gas turbine ; blowing ratio
Sažetak
Turbine blades operate under a harsh environmental condition, and the inlet temperature of gas turbines is increasing with requirement of high engine efficiency. Some cooling schemes are adopted to prevent the blades from the thermal erosion of the hot mainstream. Film cooling technology is used widely and effectively in gas turbines. The coolant air is suppressed to the wall by the mainstream after jetting out of the film hole. A new hole configuration was first proposed to improve the film cooling characteristics in this paper. Comparison between the conventional cylindrical hole and the new combined hole was conducted by computational fluid dynamics, and an effect of various blowing ratios were also investigated. Results show that the film cooling effectiveness for the combined hole configuration is higher than the conventional cylindrical hole, because the attachment from the coolant flow to the wall is weak at a high blowing ratio.
Izvorni jezik
Engleski
Znanstvena područja