Improving Lightning Location System and Advance Control, Maintenance and Planning of Transmission Power System using Lightning Location System Data


Stipetić, Nina; Franc, Bojan; Uglešić, Ivo; Mesić, Miroslav; Ivanković, Igor
Improving Lightning Location System and Advance Control, Maintenance and Planning of Transmission Power System using Lightning Location System Data // International Colloquium on Lightning and Power Systems, Ljubljana 2017 / Babuder, Maks ; Pack, Stephan (ur.).
Ljubljana: CIGRÉ, 2017. str. 1-10 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 896416 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Improving Lightning Location System and Advance Control, Maintenance and Planning of Transmission Power System using Lightning Location System Data

Autori
Stipetić, Nina ; Franc, Bojan ; Uglešić, Ivo ; Mesić, Miroslav ; Ivanković, Igor

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
International Colloquium on Lightning and Power Systems, Ljubljana 2017 / Babuder, Maks ; Pack, Stephan - Ljubljana : CIGRÉ, 2017, 1-10

Skup
International Colloquium on Lightning and Power Systems, ICLPS 2017

Mjesto i datum
Ljubljana, Slovenija, 18.09.2017. - 20.09.2017

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Lightning locating systems, transmission power system, power system control, lightning induced faults, correlation, CB operations

Sažetak
Complete lightning data were collected using lightning locating system (LLS) in Croatia by the Croatian transmission system operator (TSO). The LLS correlation system runs as a part of the National control center’s utility function, collecting lightning data and correlating with network data in real-time. The real-time lightning correlator function relies upon SCADA to acquire network faults, circuit breaker (CB) operations and relay protection data. Geographic information system (GIS) functionality was integrated into the LLS correlation system in order to make the spatial correlation between lightning strokes and network events. Lightning data are available since 2009 and lightning correlated faults data since 2013, providing full eight and four years, respectively, of precise and comprehensive data inputs from LLS, SCADA and GIS systems. Network planning processes are improved by using statistical and spatial analyses results of lightning correlated data as additional inputs for transmission line reconstruction, modernization and designs of new transmission lines. Lightning statistics for the Croatian transmission network will be presented in this paper to prove a context for the lightning related statistics of the observed transmission network. Statistical analyses on lightning correlated data are conducted taking into account 339 transmission lines of 110, 220 and 400 kV, with total length of 8 458 km. Latest improvements of the system will be presented as well as an example of spatial analyses of transmission lines containing critical segments.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika

Napomena
Paper, S1_3, 114



POVEZANOST RADA


Projekti:
HRZZ-IP-2013-11-9299 - Razvoj naprednih visokonaponskih sustava primjenom novih informacijskih i komunikacijskih tehnologija (DAHVAT) (Uglešić, Ivo, HRZZ ) ( CroRIS)

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Bojan Franc (autor)

Avatar Url Igor Ivanković (autor)

Avatar Url Nina Stipetić (autor)

Avatar Url Ivo Uglešić (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada

Citiraj ovu publikaciju:

Stipetić, Nina; Franc, Bojan; Uglešić, Ivo; Mesić, Miroslav; Ivanković, Igor
Improving Lightning Location System and Advance Control, Maintenance and Planning of Transmission Power System using Lightning Location System Data // International Colloquium on Lightning and Power Systems, Ljubljana 2017 / Babuder, Maks ; Pack, Stephan (ur.).
Ljubljana: CIGRÉ, 2017. str. 1-10 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Stipetić, N., Franc, B., Uglešić, I., Mesić, M. & Ivanković, I. (2017) Improving Lightning Location System and Advance Control, Maintenance and Planning of Transmission Power System using Lightning Location System Data. U: Babuder, M. & Pack, S. (ur.)International Colloquium on Lightning and Power Systems, Ljubljana 2017.
@article{article, author = {Stipeti\'{c}, Nina and Franc, Bojan and Ugle\v{s}i\'{c}, Ivo and Mesi\'{c}, Miroslav and Ivankovi\'{c}, Igor}, year = {2017}, pages = {1-10}, keywords = {Lightning locating systems, transmission power system, power system control, lightning induced faults, correlation, CB operations}, title = {Improving Lightning Location System and Advance Control, Maintenance and Planning of Transmission Power System using Lightning Location System Data}, keyword = {Lightning locating systems, transmission power system, power system control, lightning induced faults, correlation, CB operations}, publisher = {CIGR\'{E}}, publisherplace = {Ljubljana, Slovenija} }
@article{article, author = {Stipeti\'{c}, Nina and Franc, Bojan and Ugle\v{s}i\'{c}, Ivo and Mesi\'{c}, Miroslav and Ivankovi\'{c}, Igor}, year = {2017}, pages = {1-10}, keywords = {Lightning locating systems, transmission power system, power system control, lightning induced faults, correlation, CB operations}, title = {Improving Lightning Location System and Advance Control, Maintenance and Planning of Transmission Power System using Lightning Location System Data}, keyword = {Lightning locating systems, transmission power system, power system control, lightning induced faults, correlation, CB operations}, publisher = {CIGR\'{E}}, publisherplace = {Ljubljana, Slovenija} }




Contrast
Increase Font
Decrease Font
Dyslexic Font