Various glycolysis inhibitor containing tubes for glucose measurement cannot be used interchangeably due to clinically unacceptable biases between them


Saračević, Andrea; Dukić, Lora; Juričić, Gordana; Milevoj Kopčinović, Lara; Mirošević, Gorana; Šimundić, Ana-Maria
Various glycolysis inhibitor containing tubes for glucose measurement cannot be used interchangeably due to clinically unacceptable biases between them // Clinical chemistry and laboratory medicine, 56 (2018), 2; 236-241 doi:10.1515/cclm-2017-0279 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 893665 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Various glycolysis inhibitor containing tubes for glucose measurement cannot be used interchangeably due to clinically unacceptable biases between them

Autori
Saračević, Andrea ; Dukić, Lora ; Juričić, Gordana ; Milevoj Kopčinović, Lara ; Mirošević, Gorana ; Šimundić, Ana-Maria

Izvornik
Clinical chemistry and laboratory medicine (1434-6621) 56 (2018), 2; 236-241

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
citrate buffer ; diabetes mellitus ; glycolysis ; glycolysis inhibitor ; preanalytical phase

Sažetak
The aim of our study was to determine the difference between glucose concentration measured 30 min after venipuncture in ice- chilled heparin plasma sample and all currently available citrate buffer-containing tubes (Greiner Glucomedics, Greiner FC Mix and Sarstedt GlucoEXACT) and still widely used sodium fluoride/potassium oxalate (NaF/Kox) tubes from Greiner. Blood was collected from 20 healthy volunteers and 20 patients with diabetes into LiH, NaF/KOx, Glucomedics, FC mix and GlucoEXACT tubes. Glucose was measured within 30 min from blood sampling in duplicate on the Architect c8000 analyzer. Mean biases between all tube types were calculated and compared to the recommended criteria (1.95%). Additionally, glucose concentrations measured in all five tube types were compared using the Friedman test. In the entire studied population, glucose concentrations measured in Glucomedics, FC mix and GlucoEXACT were higher (7.3%, 3.2% and 2.0%, respectively) than in the ice-chilled LiH tubes. When all glycolysis inhibitor-containing tubes were compared, Glucomedics tubes significantly differed from GlucoEXACT and FC mix tubes (biases −4.9% and 4.0%, respectively). In addition, there was a significant difference between the NaF/KOx tube and Glucomedics, as well as FC mix tubes (biases 7.1% and 3.0%, respectively). Glucose concentrations measured in recommended ice-chilled lithium heparin- and citrate buffer-containing tubes are not comparable. Significant biases exist between various glycolysis inhibitor-containing tubes ; therefore, they cannot be used interchangeably.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti

Napomena
Rad/časopis indeksiran je i u bazama: Pathway Studio ; Primo Central (ExLibris) ; ProQuest ; Rad/časopis je indeksiran i u Bazama: Pathway Studio ; Primo Central ; ProQuestPublons ; PubsHub ; QOAM ; ReadCube ; Reaxys ; SCImago (SJR) ; Sherpa/RoMEO ; Summon ; TDNet ; TEMA ; Text Mining ; ulrichsweb ; WanFang Data ; WorldCat



POVEZANOST RADA


Ustanove:
Klinička bolnica "Sveti Duh",
KBC "Sestre Milosrdnice",
Opća bolnica Pula

Poveznice na cjeloviti tekst rada:

doi www.degruyter.com doi.org

Citiraj ovu publikaciju:

Saračević, Andrea; Dukić, Lora; Juričić, Gordana; Milevoj Kopčinović, Lara; Mirošević, Gorana; Šimundić, Ana-Maria
Various glycolysis inhibitor containing tubes for glucose measurement cannot be used interchangeably due to clinically unacceptable biases between them // Clinical chemistry and laboratory medicine, 56 (2018), 2; 236-241 doi:10.1515/cclm-2017-0279 (međunarodna recenzija, članak, znanstveni)
Saračević, A., Dukić, L., Juričić, G., Milevoj Kopčinović, L., Mirošević, G. & Šimundić, A. (2018) Various glycolysis inhibitor containing tubes for glucose measurement cannot be used interchangeably due to clinically unacceptable biases between them. Clinical chemistry and laboratory medicine, 56 (2), 236-241 doi:10.1515/cclm-2017-0279.
@article{article, author = {Sara\v{c}evi\'{c}, Andrea and Duki\'{c}, Lora and Juri\v{c}i\'{c}, Gordana and Milevoj Kop\v{c}inovi\'{c}, Lara and Miro\v{s}evi\'{c}, Gorana and \v{S}imundi\'{c}, Ana-Maria}, year = {2018}, pages = {236-241}, DOI = {10.1515/cclm-2017-0279}, keywords = {citrate buffer, diabetes mellitus, glycolysis, glycolysis inhibitor, preanalytical phase}, journal = {Clinical chemistry and laboratory medicine}, doi = {10.1515/cclm-2017-0279}, volume = {56}, number = {2}, issn = {1434-6621}, title = {Various glycolysis inhibitor containing tubes for glucose measurement cannot be used interchangeably due to clinically unacceptable biases between them}, keyword = {citrate buffer, diabetes mellitus, glycolysis, glycolysis inhibitor, preanalytical phase} }
@article{article, author = {Sara\v{c}evi\'{c}, Andrea and Duki\'{c}, Lora and Juri\v{c}i\'{c}, Gordana and Milevoj Kop\v{c}inovi\'{c}, Lara and Miro\v{s}evi\'{c}, Gorana and \v{S}imundi\'{c}, Ana-Maria}, year = {2018}, pages = {236-241}, DOI = {10.1515/cclm-2017-0279}, keywords = {citrate buffer, diabetes mellitus, glycolysis, glycolysis inhibitor, preanalytical phase}, journal = {Clinical chemistry and laboratory medicine}, doi = {10.1515/cclm-2017-0279}, volume = {56}, number = {2}, issn = {1434-6621}, title = {Various glycolysis inhibitor containing tubes for glucose measurement cannot be used interchangeably due to clinically unacceptable biases between them}, keyword = {citrate buffer, diabetes mellitus, glycolysis, glycolysis inhibitor, preanalytical phase} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka::


  • Analytical Abstracts
  • CA Search (Chemical Abstracts)
  • EMBASE (Excerpta Medica)
  • Baidu Scholar
  • Biobase
  • CABI
  • Case
  • CNKI Scholar
  • CNPIEC
  • EBSCO
  • Gale/Cengage
  • Genamics JournalSeek
  • Google Scholar
  • ICAP Alcohol Information Databases
  • J-Gate
  • JCReports/Science Edition
  • JournalGuide
  • JournalTOCs
  • JST
  • KESLI-NDSL
  • Meta
  • Microsoft Academic
  • Naviga (Softweco
  • Norwegian Register for Scientific Journals


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font