Pregled bibliografske jedinice broj: 890757
Flying Start of a Permanent Magnet Wind Power Generator Based on a Discontinuous Converter Operation Mode and a Phase-Locked Loop
Flying Start of a Permanent Magnet Wind Power Generator Based on a Discontinuous Converter Operation Mode and a Phase-Locked Loop // IEEE transactions on industrial electronics, 65 (2018), 1097-1106 doi:10.1109/TIE.2017.2733453 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 890757 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Flying Start of a Permanent Magnet Wind Power Generator Based on a Discontinuous Converter Operation Mode and a Phase-Locked Loop
Autori
Pravica, Luka ; Sumina, Damir ; Bariša, Tin ; Kovačić, Marinko ; Čolović, Igor
Izvornik
IEEE transactions on industrial electronics (0278-0046) 65
(2018);
1097-1106
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Rotors, Generators, Phase locked loops, Stators, Short-circuit currents, Pulse width modulation, Insulated gate bipolar transistors
Sažetak
Flying start of a wind generator is a common requirement in wind turbine applications. This paper proposes a novel method for allowing the flying start of a permanent magnet generator (PMG). The proposed method is based on the discontinuous mode of operation of the converter and the phase-locked loop (PLL). During the discontinuous mode of operation a series of zero-voltage pulses is applied to the generator causing the occurrence of the short circuit current, and thereby employing the PLL structure to estimate the rotor speed and angle. Also, a short circuit current control structure with automatic adjustment of the reference value is proposed. The input signal to a PLL structure is adequately selected in order to enable a continuous mode of operation of the PMG. Simulation results demonstrate the applicability of the proposed method on surface and interior PMGs, as well as on low and high power PMGs. The estimation accuracy does not depend on changes in the PMG parameters. The proposed method was implemented in a digital control system and experimentally verified on a 375 kW interior PMG. Experimental responses referring to the flying start of the PMG demonstrate the effectiveness of the proposed method.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
HRZZ-UIP-2013-11-7601 - Razvoj naprednih energetski učinkovitih struktura upravljanja generatorom sa stalnim magnetima bez mjernog člana (PMGEFC) (Sumina, Damir, HRZZ ) ( CroRIS)
Ustanove:
KONČAR - Institut za elektrotehniku d.d.,
Fakultet elektrotehnike i računarstva, Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus