Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 883022

Comfort Control in Buildings with Adherence to the Required Thermal Energy Input in Zones


Martinčević, Anita; Rukavina, Filip; Lešić, Vinko; Vašak, Mario
Comfort Control in Buildings with Adherence to the Required Thermal Energy Input in Zones // Proceedings of the 2017 IEEE International Symposium on Industrial Electronics
Edinburgh, 2017. str. 1477-1482 doi:10.1109/ISIE.2017.8001464 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 883022 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comfort Control in Buildings with Adherence to the Required Thermal Energy Input in Zones

Autori
Martinčević, Anita ; Rukavina, Filip ; Lešić, Vinko ; Vašak, Mario

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the 2017 IEEE International Symposium on Industrial Electronics / - Edinburgh, 2017, 1477-1482

ISBN
978-1-5090-1411-8

Skup
IEEE International Symposium on Industrial Electronics

Mjesto i datum
Edinburgh, Ujedinjeno Kraljevstvo, 19.06.2017. - 21.06.2017

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Model Predictive Control ; Energy management ; Zone temperature control ; Fan Coil Unit

Sažetak
This paper focusses on implementation of the energy management in building zones with fan coil units. The implementation is based on direct control of the required thermal energy inputs. We develop it as a necessary add-on to model predictive control algorithms that use thermal models of a building and compute the optimal energy inputs in different building zones for minimization of the overall energy cost required to keep the thermal comfort. The presented approach is substantially different to the generally accepted temperature control via local reactive control that only uses local measurements in deciding the control actions for zones thermal actuators. We demonstrate that closed loop performance, spent energy and the users comfort, is significantly improved over conventional control approaches. The model of a fan coil unit is identified and validated based on real data gathered from the living lab of University of Zagreb Faculty of Electrical Engineering and Computing. This model is then used for the subsequent control development and validation of the overall control approach via simulations.

Izvorni jezik
Engleski

Znanstvena područja
Matematika, Elektrotehnika



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Mario Vašak (autor)

Avatar Url Vinko Lešić (autor)

Avatar Url Anita Banjac (autor)

Avatar Url Filip Rukavina (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada doi ieeexplore.ieee.org

Citiraj ovu publikaciju:

Martinčević, Anita; Rukavina, Filip; Lešić, Vinko; Vašak, Mario
Comfort Control in Buildings with Adherence to the Required Thermal Energy Input in Zones // Proceedings of the 2017 IEEE International Symposium on Industrial Electronics
Edinburgh, 2017. str. 1477-1482 doi:10.1109/ISIE.2017.8001464 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Martinčević, A., Rukavina, F., Lešić, V. & Vašak, M. (2017) Comfort Control in Buildings with Adherence to the Required Thermal Energy Input in Zones. U: Proceedings of the 2017 IEEE International Symposium on Industrial Electronics doi:10.1109/ISIE.2017.8001464.
@article{article, author = {Martin\v{c}evi\'{c}, Anita and Rukavina, Filip and Le\v{s}i\'{c}, Vinko and Va\v{s}ak, Mario}, year = {2017}, pages = {1477-1482}, DOI = {10.1109/ISIE.2017.8001464}, keywords = {Model Predictive Control, Energy management, Zone temperature control, Fan Coil Unit}, doi = {10.1109/ISIE.2017.8001464}, isbn = {978-1-5090-1411-8}, title = {Comfort Control in Buildings with Adherence to the Required Thermal Energy Input in Zones}, keyword = {Model Predictive Control, Energy management, Zone temperature control, Fan Coil Unit}, publisherplace = {Edinburgh, Ujedinjeno Kraljevstvo} }
@article{article, author = {Martin\v{c}evi\'{c}, Anita and Rukavina, Filip and Le\v{s}i\'{c}, Vinko and Va\v{s}ak, Mario}, year = {2017}, pages = {1477-1482}, DOI = {10.1109/ISIE.2017.8001464}, keywords = {Model Predictive Control, Energy management, Zone temperature control, Fan Coil Unit}, doi = {10.1109/ISIE.2017.8001464}, isbn = {978-1-5090-1411-8}, title = {Comfort Control in Buildings with Adherence to the Required Thermal Energy Input in Zones}, keyword = {Model Predictive Control, Energy management, Zone temperature control, Fan Coil Unit}, publisherplace = {Edinburgh, Ujedinjeno Kraljevstvo} }

Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font