Pregled bibliografske jedinice broj: 883002
Control material for external quality assessment in haematology
Control material for external quality assessment in haematology // Biochemia Medica / Šimundić, Ana-Maria (ur.).
Zagreb: Hrvatsko društvo za medicinsku biokemiju i laboratorijsku medicinu (HDMBLM), 2016. str. A3-A3 (pozvano predavanje, međunarodna recenzija, sažetak, stručni)
CROSBI ID: 883002 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Control material for external quality assessment in haematology
Autori
Ćelap, Ivana
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni
Izvornik
Biochemia Medica
/ Šimundić, Ana-Maria - Zagreb : Hrvatsko društvo za medicinsku biokemiju i laboratorijsku medicinu (HDMBLM), 2016, A3-A3
Skup
27th Symposium of Croatian Society of Medical Biochemistry and Laboratory Medicine
Mjesto i datum
Zagreb, Hrvatska, 10.09.2016
Vrsta sudjelovanja
Pozvano predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
vanjska procjena kvalitete, kontrolni uzorak za lab hematologiju
(EQA, lab haematology control samples)
Sažetak
As in other laboratory diagnostic fields, the main goal of external quality assessment (EQA) in haematology is to achieve the lowest possible interlaboratory variation for haematological parameters since those parameters are mainly used for monitoring purposes and the differences between two patient results should not be jeopardized by analytical variation between different cell counting principles. Commercial control materials made for EQA purposes are, mostly, analyser specific. Specificity comes out of striving to achieve long term stability of the control material. Manufactures use different approaches to resolve stability issues. Usually, controls are made of preserved and stabilised fresh human blood and/or by addition of surrogate materials (avian, porcine, bovine etc. cells) in leucocytes and platelets deprived blood. Control materials prepared in such way result with morphologically altered red blood cells causing problems in cell counting when obtained by different analysers. Consequently, comparability of the results could be threatened. The best, i.e. commutable control material for interlaboratory comparison in haematology is the fresh blood sample. Despite of its indisputable advantages, that kind of sample has numerous disadvantages which EQA providers must overcome if want fresh blood sample serve as a control material in their haematology scheme. The main reason not using fresh human blood for EQA in haematology is short stability and limited blood volume which can be obtained from donor. To overcome stability problems every EQA provider uses different receipt. The most convenient solution is minimal preservation of blood cells in order to keep the morphological characteristics of the cells. However, maximum stability still could not be longer than a few days. CROQALM successfully provided 3 exercises in haematology scheme using human fresh blood as a control sample. Since haematology scheme has nearly 180 participants, blood dose from single donor is enough to ensure that every laboratory obtains sufficient volume for analysis. Stability issues are overcame by postal delivery within 48 hours.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- Scopus