Pregled bibliografske jedinice broj: 881973
Structural investigation of organic compounds and their complexes by ESI MS/MS
Structural investigation of organic compounds and their complexes by ESI MS/MS // Proceedings of 4th World Congress on Mass Spectrometry
London, Ujedinjeno Kraljevstvo, 2017. str. 96-96 (pozvano predavanje, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 881973 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Structural investigation of organic compounds and their complexes by ESI MS/MS
Autori
Galić, Nives
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Proceedings of 4th World Congress on Mass Spectrometry
/ - , 2017, 96-96
Skup
4th World Congress on Mass Spectrometry
Mjesto i datum
London, Ujedinjeno Kraljevstvo, 19.06.2017. - 21.06.2017
Vrsta sudjelovanja
Pozvano predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Tandem mass spectrometry ; Hydrazones, Calixarenes, Bivalirudin
Sažetak
The application of electrospray tandem mass spectrometry (ESI MS/MS) in organic analysis, as well as in pharmaceutical industry, will be presented and discussed on several examples as follows: 1. Structural isomers of aromatic hydrazones derived from nicotinic acid hydrazide were identified due to comprehensive study of their fragmentation pathways. Isomers derived from 3- and 4-hydroxy salicylaldehyde, as well as those derived from 3- and 5-chloro salicylaldehyde were distinguished due to "ortho effect". The MS/MS spectra and fragmentation pathways of compounds derived from 3- and 4-methoxy salicylaldehyde differ due to enolimino- ketoamino tautomeric interconversion of one isomer. 2. Peptidocalixarenes bearing tryptophan, phenylglycine and leucine at the lower rim and their complexes with alkali-metal (Li+, Na+, K+, Rb+, Cs+) and selected lanthanide cations (La3+, Ce3+, Eu3+, Yb3+) were analyzed by ESI MS/MS. The results of MS analysis were in accordance with those obtained by other techniques (spectrophotometric, potentiometric, and conductometric titrations). The MS/MS experiments could be used as fast and sensitive method for prediction of relative stabilities of calixarene complexes with metal ions. 3. Bivalirudin, a synthetic oligopeptide, is used as anticoagulant for patients with acute coronary syndromes or patients undergoing percutaneous coronary intervention. Forced degradation studies were performed using acid, base, H2O2, heat and light exposure as recommended by the International Conference on Harmonization (ICH). An UPLC method with UV detection for determination of bivalirudin in the presence of its degradation products has been developed. However, for the identification of degradation products the 2D LC MS/MS system had to be used.
Izvorni jezik
Engleski
Znanstvena područja
Kemija