Pregled bibliografske jedinice broj: 88182
Chemically treated silver electrodes for the determination of cysteine
Chemically treated silver electrodes for the determination of cysteine // Mikrochimica Acta, 138 (2002), 1-2; 23-27 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 88182 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Chemically treated silver electrodes for the determination of cysteine
Autori
Kolar, M ; Dobčnik, D ; Radić, Nj
Izvornik
Mikrochimica Acta (0026-3672) 138
(2002), 1-2;
23-27
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Cysteine; Potentiometry; Ion-selective electrodes; Flow injection potentiometry; Chemically treated electrode surface; Flow-injection determination.
Sažetak
This paper describes the use of Ag/Ag2S and Ag/AgI ion-selective electrodes by means of chemical pretreatment of a silver wire or tube for the determination of cysteine (RSH) in batch and flow injection analysis (FIA). Batch experiments were made with a Ag/Ag2S wire electrode in an acidic medium (0.1 mol/l HClO4) in water solutions. Equilibrium potentials measured by the serial dilution of Ag+ and serial addition of cysteine at constant ionic-strength and pH are shown in dependence on log c(Ag+) and log c(cys) and for cysteine indicate constant linear response within the concentration range between 3.1 x 10(-5) and 2.0 x 10(-2) mol/l at the slope of 56.7+/-1.0 mV {p(cys)}(-1). These results suggest the formation of an RSAg layer on the exposed electrode surface. In the FIA a carrier stream containing 1.0 x 10(-5) mol/l Ag+ + 0.1 mol/l HClO4 was used and the Ag/Ag2S electrode was then characterised by a constant linear response within the concentration range between 5.0 x 10(-5) and 5.0 x 10(-3) mol/l at the slope of 53.4+/-1.0 mV {p(cys)}(-1). Measurements of cysteine with Ag/AgI electrode are enabled by the reduction of iodine in the carrier stream. At optimum FIA parameters (flow rate, tube length, sample volume and the composition of the carrier stream were optimised) the electrode is characterised by a constant linear response within the concentration range between 5.0 x 10(-5) and 1.0 x 10(-2) Mol/l at the slope of 59.9 1.0 mV {p(cys)}(-1).
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus