Pregled bibliografske jedinice broj: 881356
One-dimensional diffusion equation for the particle size distribution of perlite filter granulation
One-dimensional diffusion equation for the particle size distribution of perlite filter granulation // Tehnički vjesnik : znanstveno-stručni časopis tehničkih fakulteta Sveučilišta u Osijeku, 24 (2017), 3; 943-948 (podatak o recenziji nije dostupan, članak, ostalo)
CROSBI ID: 881356 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
One-dimensional diffusion equation for the particle size distribution of perlite filter granulation
Autori
Tomantschger, Kurt ; Petrović, Dragan ; Radojević, Rade ; Golubović, Zorana ; Tadić, Vjekoslav
Izvornik
Tehnički vjesnik : znanstveno-stručni časopis tehničkih fakulteta Sveučilišta u Osijeku (1330-3651) 24
(2017), 3;
943-948
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, ostalo
Ključne riječi
filter granulation ; morphometric method ; partial differential equation ; particle size distribution ; perlite
Sažetak
Many filtration systems employing perlite granulations have been designed so far. Size distribution of perlite particles directly influences the retention properties of filter media. The information on the size distribution of perlite particles, used in each specific dead-end filtration process (the flow of fluid being filtered is perpendicular to the surface of filter medium), is crucial for the adequate design of filter medium. In order to facilitate the design of filter systems possessing filter media of this kind, a new and particular mathematical model has been developed for this present study. It is based on an appropriate partial differential equation and additional mathematical conditions, whose solution is an exponential function describing the probability density distribution of perlite particle sizes. The formulated model was experimentally verified by measuring the particle sizes of a perlite granulation using the morphometric method, based on the application of a standard light microscope and digital image analysis software. The fitting procedure of experimental data gave acceptable values of accuracy parameters - high R-square factor (R2 = 0, 905) and small value of the root-mean square error (MSE = 0, 490).
Izvorni jezik
Engleski
Znanstvena područja
Poljoprivreda (agronomija)
POVEZANOST RADA
Ustanove:
Fakultet agrobiotehničkih znanosti Osijek
Profili:
Vjekoslav Tadić
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus