Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 877184

Investigation of Primary Dew-Point Saturator Efficiency in Two Different Thermal Environments


Zvizdić, Davor; Heinonen, Martti; Sestan, Danijel
Investigation of Primary Dew-Point Saturator Efficiency in Two Different Thermal Environments // International journal of thermophysics, 36 (2015), 8; 2215-2230 doi:10.1007/s10765-015-1899-y (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 877184 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Investigation of Primary Dew-Point Saturator Efficiency in Two Different Thermal Environments

Autori
Zvizdić, Davor ; Heinonen, Martti ; Sestan, Danijel

Izvornik
International journal of thermophysics (0195-928X) 36 (2015), 8; 2215-2230

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Dew point ; Dew-point generator ; Frost point Humidity standard ; Saturator efficiency ; Single-pressure generator

Sažetak
The aim of this paper is to describe the evaluation process of the performance of the low-range saturator (LRS), when exposed to two different thermal environments. The examined saturator was designed, built, and tested at MIKES (Centre for Metrology and Accreditation, Finland), and then transported to the Laboratory for Process Measurement (LPM) in Croatia, where it was implemented in a new dew- point calibration system. The saturator works on a single-pressure–single-pass generation principle in the dew/frost-point temperature range between −70 ∘C and +5 ∘C. The purpose of the various tests performed at MIKES was to examine the efficiency and non-ideality of the saturator. As a test bath facility in Croatia differs from the one used in Finland, the same tests were repeated at LPM, and the effects of different thermal conditions on saturator performance were examined. Thermometers, pressure gauges, an air preparation system, and water for filling the saturator at LPM were also different than those used at MIKES. Results obtained by both laboratories indicate that the efficiency of the examined saturator was not affected either by the thermal conditions under which it was tested or by equipment used for the tests. Both laboratories concluded that LRS is efficient enough for a primary realization of the dew/frost-point temperature scale in the range from −70 ∘C to +5 ∘C , with flow rates between 1 L⋅min−1 and 2.5 L⋅min−1. It is also shown that a considerable difference of the pre-saturator efficiency, indicated by two laboratories, did not have influence to the overall performance of the saturator. The results of the research are presented in graphical and tabular forms. This paper also gives a brief description of the design and operation principle of the investigated low-range saturator.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Projekti:
120-0000000-3322 - Razvoj nacionalnog etalona temperature (Zvizdić, Davor, MZOS ) ( CroRIS)

Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb

Profili:

Avatar Url Danijel Šestan (autor)

Avatar Url Davor Zvizdić (autor)

Poveznice na cjeloviti tekst rada:

doi link.springer.com

Citiraj ovu publikaciju:

Zvizdić, Davor; Heinonen, Martti; Sestan, Danijel
Investigation of Primary Dew-Point Saturator Efficiency in Two Different Thermal Environments // International journal of thermophysics, 36 (2015), 8; 2215-2230 doi:10.1007/s10765-015-1899-y (međunarodna recenzija, članak, znanstveni)
Zvizdić, D., Heinonen, M. & Sestan, D. (2015) Investigation of Primary Dew-Point Saturator Efficiency in Two Different Thermal Environments. International journal of thermophysics, 36 (8), 2215-2230 doi:10.1007/s10765-015-1899-y.
@article{article, author = {Zvizdi\'{c}, Davor and Heinonen, Martti and Sestan, Danijel}, year = {2015}, pages = {2215-2230}, DOI = {10.1007/s10765-015-1899-y}, keywords = {Dew point, Dew-point generator, Frost point Humidity standard, Saturator efficiency, Single-pressure generator}, journal = {International journal of thermophysics}, doi = {10.1007/s10765-015-1899-y}, volume = {36}, number = {8}, issn = {0195-928X}, title = {Investigation of Primary Dew-Point Saturator Efficiency in Two Different Thermal Environments}, keyword = {Dew point, Dew-point generator, Frost point Humidity standard, Saturator efficiency, Single-pressure generator} }
@article{article, author = {Zvizdi\'{c}, Davor and Heinonen, Martti and Sestan, Danijel}, year = {2015}, pages = {2215-2230}, DOI = {10.1007/s10765-015-1899-y}, keywords = {Dew point, Dew-point generator, Frost point Humidity standard, Saturator efficiency, Single-pressure generator}, journal = {International journal of thermophysics}, doi = {10.1007/s10765-015-1899-y}, volume = {36}, number = {8}, issn = {0195-928X}, title = {Investigation of Primary Dew-Point Saturator Efficiency in Two Different Thermal Environments}, keyword = {Dew point, Dew-point generator, Frost point Humidity standard, Saturator efficiency, Single-pressure generator} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font