Pregled bibliografske jedinice broj: 874818
Thermodynamical analysis of high-pressure feed water heater in steam propulsion system during exploitation
Thermodynamical analysis of high-pressure feed water heater in steam propulsion system during exploitation // Brodogradnja, 68 (2017), 2; 45-61 doi:10.21278/brod68204 (domaća recenzija, prethodno priopćenje, znanstveni)
CROSBI ID: 874818 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Thermodynamical analysis of high-pressure feed water heater in steam propulsion system during exploitation
Autori
Mrzljak, Vedran ; Poljak, Igor ; Medica-Viola, Vedran
Izvornik
Brodogradnja (0007-215X) 68
(2017), 2;
45-61
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, prethodno priopćenje, znanstveni
Ključne riječi
High-pressure feed water heater ; Energy efficiency ; Energetic power loss ; Exergy efficiency ; Exergetic power loss
Sažetak
Nowadays diesel engines prevail as ship propulsion. However, steam propulsion is still primary drive for LNG carriers. In the presented paper high-pressure feed water heater was analyzed, as one of the essential components in LNG carrier steam propulsion system. Measurements of all operating parameters (fluid streams) at the analyzed heat exchanger inlets and outlets were performed. Change of the operating parameters was measured at different steam system loads, not at full load as usual. Through these measurements was enabled the insight into the behaviour of the heat exchanger operating parameters during the whole exploitation. The numerical analysis was performed, based on the measured data. The changes in energy and exergy efficiency of the heat exchanger were analyzed. Energetic and exergetic power inputs and outputs were also calculated, which enabled an insight into the change of energetic and exergetic power losses of the heat exchanger at different steam system loads. Change in energetic and exergetic power losses and operating parameters, which have the strongest influence on the high-pressure feed water heater losses, were described. Analyzed heat exchanger was compared with similar heat exchangers in the base loaded conventional steam power plants. From the conducted analysis, it is concluded that the adjustment and control modes of these high- pressure heat exchangers are equal, regardless of whether they were mounted in the base loaded conventional steam power plants or marine steam systems, while their operating parameters and behaviour patterns differ greatly.
Izvorni jezik
Engleski
Znanstvena područja
Strojarstvo
POVEZANOST RADA
Ustanove:
Tehnički fakultet, Rijeka
Citiraj ovu publikaciju:
Časopis indeksira:
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
Uključenost u ostale bibliografske baze podataka::
- Journal Citation Reports® Science Edition