Pregled bibliografske jedinice broj: 874801
Frequency response and harmonic distortion testing of inductive voltage transformer used for power quality measurements
Frequency response and harmonic distortion testing of inductive voltage transformer used for power quality measurements // 4th International Colloquium "Transformer Research and Asset Management", Pula, Croatia, May 10 – 12, 2017
Zagreb: CIGRÉ, 2017. str. 1-9 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 874801 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Frequency response and harmonic distortion testing of inductive voltage transformer used for power quality measurements
Autori
Filipović-Grčić, Dalibor ; Filipović-Grčić, Božidar ; Krajtner, Danijel
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
4th International Colloquium "Transformer Research and Asset Management", Pula, Croatia, May 10 – 12, 2017
/ - Zagreb : CIGRÉ, 2017, 1-9
Skup
4th International Colloquium "Transformer Research and Asset Management"
Mjesto i datum
Pula, Hrvatska, 10.05.2017. - 12.05.2017
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Inductive voltage transformer ; frequency response ; harmonic distortion ; power quality ; high voltage testing
Sažetak
International standards related to power quality measurements define methods and accuracies for the measuring instruments, but do not specify the accuracy of instrument transformers. Therefore, it is not possible to specify an overall accuracy for such measurements. Inductive voltage transformers (IVTs) which are used for power quality measurements should be tested to determine the ratio correction factors (RCFs) and phase angle errors at higher frequencies. In this paper, harmonic distortion and frequency response tests are performed to determine the level of harmonics generated by IVT and its ability to transform harmonics from high voltage (HV) to low voltage (LV) side. Complex voltages consisting of fundamental voltage and certain amount of superimposed harmonic are used to check the frequency response of IVT. RCFs and phase angle errors of the IVT are determined and can be applied to power quality monitors for compensation of errors that occur at high harmonic frequencies. Different test circuits are proposed for generation of HV consisting of fundamental voltage and harmonic voltages with amplitudes in range 5-15 % of the applied fundamental voltage. In order to improve the testing capabilities at higher voltage levels (for equipment with 123 kV≤Um≤420 kV), a compensation for both fundamental and harmonic voltages is proposed with a special connection through blocking and pass filters.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Ustanove:
KONČAR - Institut za elektrotehniku d.d.,
Fakultet elektrotehnike i računarstva, Zagreb