Pregled bibliografske jedinice broj: 873367
Amperometric determination of L-cysteine with an electrode based on ternary silver-copper sulfide
Amperometric determination of L-cysteine with an electrode based on ternary silver-copper sulfide // 25. HRVATSKI SKUP KEMIČARA I KEMIJSKIH INŽENJERA s međunarodnim sudjelovanjem / Ana Šantić, Marijana Đaković (ur.).
Zagreb: Hrvatsko knjižničarsko društvo, 2017. str. 256-256 (poster, domaća recenzija, sažetak, znanstveni)
CROSBI ID: 873367 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Amperometric determination of L-cysteine with an electrode based on ternary silver-copper sulfide
Autori
Krivić, Denis ; Buzuk Marijo ; Buljac, Maša ; Vladislavić, Nives ; Škugor Rončević, Ivana ; Bralić, Marija ; Brinić Slobodan
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
25. HRVATSKI SKUP KEMIČARA I KEMIJSKIH INŽENJERA s međunarodnim sudjelovanjem
/ Ana Šantić, Marijana Đaković - Zagreb : Hrvatsko knjižničarsko društvo, 2017, 256-256
Skup
25. HRVATSKI SKUP KEMIČARA I KEMIJSKIH INŽENJERA s međunarodnim sudjelovanjem
Mjesto i datum
Poreč, Hrvatska, 19.04.2017. - 22.04.2017
Vrsta sudjelovanja
Poster
Vrsta recenzije
Domaća recenzija
Ključne riječi
amperometic, electroanalytic, cysteine, ternary crystal sulfides electrode
Sažetak
A simple method for amperometric determination of L-cysteine using an electrode based on ternary silver-copper sulfide is presented. Electrochemical characterizations (by cyclic voltammetry) of three electrode materials, prepared under different conditions, has revealed that the electrode based on material that consists of jalpaite (Ag3CuS2) doped with a small amount of metallic silver [1-2] (proven through the usage of XRD pattern) has shown the best electrocatalytical performance for L-cysteine oxidation. For amperometric determination, electrocatalytical oxidation of thiol group at 0.04 V vs. Ag/AgCl has been chosen. Electrochemical impedance spectroscopy has revealed that oxidation takes place on electrode surface without fouling effect, which provides a wide linear working range between 0.5 μmol dm-3 and 100 μmol dm-3. The electrode could be operated with at pH that was between 4 and 8, although the best performance has been obtained under physiological conditions (pH 7-7, 5). The calculated detection limit based on 3σ criterion was 0.025 μmol dm-3, with sensitivity of 55 nA μmol-1 dm3. In the presence of uric acid, folic acid, ascorbic acid and glucose no interference has been noticed. This amperometric sensor has shown remarkable stability and excellent reproducibility. The sensor was exploited for determination of L-cysteine in a dietary supplement with excellent recoveries.