Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots.


Nikolac, Nora; Leniček Krleža, Jasna; Šimundić, Ana- Maria
Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots. // Biochemia medica : časopis hrvatskoga društva medicinskih biokemičara, 27 (2017), 1; 131-143 doi:10.11613/BM.2017.017 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 861140 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots.

Autori
Nikolac, Nora ; Leniček Krleža, Jasna ; Šimundić, Ana- Maria

Izvornik
Biochemia medica : časopis hrvatskoga društva medicinskih biokemičara (1330-0962) 27 (2017), 1; 131-143

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Preanalytical phase ; External quality assessment ; Laboratory error

Sažetak
Introduction: The aim of this paper is to present results of first two years of preanalytical external quality assessment (EQA) in Croatia. Materials and methods: This paper summarizes results from 6 rounds of preanalytical EQA during 2014-2016 in 161-175 Croatian laboratories (number ranged between cycles). EQA was designed as an online survey of the compliance with National recommendations for phlebotomy (NRP). Forty-seven questions in 5 categories are analyzed (materials and equipment, patient identification, patient preparation, sampling and storage). Additionally, preanalytical cases are presented. Overall performance scores (Question score (Qscore) for compliance with NRP and Case score (Cscore) for preanalytical cases) are calculated for each question/case as a proportion of laboratories with satisfactory procedure (x 100). Qscores and Cscores ≥ 70 were classified as acceptable (maximal score = 100). Results: In investigation of compliance with NRP, acceptable Qscores were obtained for 34/47 questions. The lowest scores were observed for the availability of sterile disposable tourniquets (Qscore = 15) and safe- sharp needles (Qscore = 34), obtaining patients address as an identifier (Qscore = 21), using glycolysis inhibitor tubes for glucose concentration measurement (Qscore = 21) and verification of manufacturers declarations on temperature and time of storage (Qscore = 31). There was no statistically significant difference in overall Qscore according to different categories of phlebotomy procedures (P = 0.284). The results of preanalytical cases showed acceptable Cscore values for all cases (89-96). Conclusion: First two years of preanalytical EQA showed good compliance with the NRP and excellent expertise in resolving complex preanalytical issues. Major critical spots are lack of availability of safe-sharp needles, disposable tourniquets and glucose inhibitor tubes.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti, Kliničke medicinske znanosti, Javno zdravstvo i zdravstvena zaštita

Napomena
S.I.: External Quality Assessment in Laboratory Medicine.



POVEZANOST RADA


Ustanove:
Klinička bolnica "Sveti Duh",
KBC "Sestre Milosrdnice",
Klinika za dječje bolesti

Citiraj ovu publikaciju:

Nikolac, Nora; Leniček Krleža, Jasna; Šimundić, Ana- Maria
Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots. // Biochemia medica : časopis hrvatskoga društva medicinskih biokemičara, 27 (2017), 1; 131-143 doi:10.11613/BM.2017.017 (međunarodna recenzija, članak, znanstveni)
Nikolac, N., Leniček Krleža, J. & Šimundić, A. (2017) Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots.. Biochemia medica : časopis hrvatskoga društva medicinskih biokemičara, 27 (1), 131-143 doi:10.11613/BM.2017.017.
@article{article, author = {Nikolac, Nora and Leni\v{c}ek Krle\v{z}a, Jasna and \v{S}imundi\'{c}, Ana- Maria}, year = {2017}, pages = {131-143}, DOI = {10.11613/BM.2017.017}, keywords = {Preanalytical phase, External quality assessment, Laboratory error}, journal = {Biochemia medica : \v{c}asopis hrvatskoga dru\v{s}tva medicinskih biokemi\v{c}ara}, doi = {10.11613/BM.2017.017}, volume = {27}, number = {1}, issn = {1330-0962}, title = {Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots.}, keyword = {Preanalytical phase, External quality assessment, Laboratory error} }
@article{article, author = {Nikolac, Nora and Leni\v{c}ek Krle\v{z}a, Jasna and \v{S}imundi\'{c}, Ana- Maria}, year = {2017}, pages = {131-143}, DOI = {10.11613/BM.2017.017}, keywords = {Preanalytical phase, External quality assessment, Laboratory error}, journal = {Biochemia medica : \v{c}asopis hrvatskoga dru\v{s}tva medicinskih biokemi\v{c}ara}, doi = {10.11613/BM.2017.017}, volume = {27}, number = {1}, issn = {1330-0962}, title = {Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots.}, keyword = {Preanalytical phase, External quality assessment, Laboratory error} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka::


  • EMBASE (Excerpta Medica)
  • MEDLINE


Citati: