Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 859828

Multifrequency bioimpedance analysis - a helping hand in precise and objective volume status control in peritoneal dialysis patients


Dorčić , Gordan; Vujičić , Božidar; Babić , Vesna; Rundić , Anamarija; Vidić , Željka; Devčić , Bosiljka; Rački , Sanjin
Multifrequency bioimpedance analysis - a helping hand in precise and objective volume status control in peritoneal dialysis patients // Book of abstracts, 6th Slovenian congress of nephrology
Portorož, Slovenija, 2016. (predavanje, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 859828 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Multifrequency bioimpedance analysis - a helping hand in precise and objective volume status control in peritoneal dialysis patients

Autori
Dorčić , Gordan ; Vujičić , Božidar ; Babić , Vesna ; Rundić , Anamarija ; Vidić , Željka ; Devčić , Bosiljka ; Rački , Sanjin

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Book of abstracts, 6th Slovenian congress of nephrology / - , 2016

ISBN
978-961-6956-52-9

Skup
6th Slovenian Congress of Nephrology

Mjesto i datum
Portorož, Slovenija, 24.11.2016. - 27.11.2016

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
volume status, peritoneal dialysis, multifrequency bioimpedance analysis

Sažetak
Background. Volume overload is a mortality and morbidity risk factor in dialysis patients. Residual renal function (RRF) in peritoneal dialysis (PD) patients remains preserved longer than in hemodialysis patients. In spite of that, PD patients are still at high risk of volume overload leading to a challenging hypertension control. Routine clinical assessment of volume status is subjective, and a new tool was needed for its more precise and objective evaluation. A multifrequency bioimpedance analysis (MF-BIA) is a simple, non-invasive and accurate tool for the evaluation of hydration status. The aim of this study was to determine the impact of long-term MF-BIA volume status assessment and volume-dependent hypertension incidence in PD patients. Methods. In this prospective trial, we included incident PD patients in Department of Nephrology, Dialysis and Kidney Transplantation, Clinical Hospital Centre Rijeka, from January 1, 2014, to December 31, 2015. MF-BIA volume status assessment was conducted every six months on a patient with the full abdomen. Additionally, we assessed systolic and diastolic blood pressure (BP) (hypertension was considered systolic/diastolic BP >140/90) and RRF. Patients who achieved at least three consecutive measurements were included in the study. PD prescription and concomitant therapy were adjusted according to BP and overhydration (OH). Results. Out of total 43 patients, 22 patients (male 63%, age 56.4±14.1 years, body mass index 25.9±2.6 kg/m², 28% diabetic, 60% continuous ambulatory PD) were analyzed. Baseline PD vintage was 9.1±7.1 months with RRF 1878.12±814.65 ml. After collecting data, hydration reference plot was made, and patients were divided into five categories depending on their BP and OH. A number of volume induced hypertensive patients decreased significantly (p=<0.01) between baseline and follow-up measurement, as well as the number of normotensive euvolemic patients increased significantly (p=<0.01). OH and systolic BP were significantly lower at the end of follow-up (p=0.01 and p<0.01, respectively). Conclusions. Using MF-BIA volume assessment resulted in significant decrease in volume overload and volume-dependent hypertension in PD patients. Average RRF didn’t decrease significantly over two years study period. Further investigations including more patients are required.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Klinički bolnički centar Rijeka

Profili:

Avatar Url Božidar Vujičić (autor)

Avatar Url Sanjin Rački (autor)


Citiraj ovu publikaciju:

Dorčić , Gordan; Vujičić , Božidar; Babić , Vesna; Rundić , Anamarija; Vidić , Željka; Devčić , Bosiljka; Rački , Sanjin
Multifrequency bioimpedance analysis - a helping hand in precise and objective volume status control in peritoneal dialysis patients // Book of abstracts, 6th Slovenian congress of nephrology
Portorož, Slovenija, 2016. (predavanje, međunarodna recenzija, sažetak, znanstveni)
Dorčić , G., Vujičić , B., Babić , V., Rundić , A., Vidić , Ž., Devčić , B. & Rački , S. (2016) Multifrequency bioimpedance analysis - a helping hand in precise and objective volume status control in peritoneal dialysis patients. U: Book of abstracts, 6th Slovenian congress of nephrology.
@article{article, author = {Dor\v{c}i\'{c}, Gordan and Vuji\v{c}i\'{c}, Bo\v{z}idar and Babi\'{c}, Vesna and Rundi\'{c}, Anamarija and Vidi\'{c}, \v{Z}eljka and Dev\v{c}i\'{c}, Bosiljka and Ra\v{c}ki, Sanjin}, year = {2016}, pages = {6}, keywords = {volume status, peritoneal dialysis, multifrequency bioimpedance analysis}, isbn = {978-961-6956-52-9}, title = {Multifrequency bioimpedance analysis - a helping hand in precise and objective volume status control in peritoneal dialysis patients}, keyword = {volume status, peritoneal dialysis, multifrequency bioimpedance analysis}, publisherplace = {Portoro\v{z}, Slovenija} }
@article{article, author = {Dor\v{c}i\'{c}, Gordan and Vuji\v{c}i\'{c}, Bo\v{z}idar and Babi\'{c}, Vesna and Rundi\'{c}, Anamarija and Vidi\'{c}, \v{Z}eljka and Dev\v{c}i\'{c}, Bosiljka and Ra\v{c}ki, Sanjin}, year = {2016}, pages = {6}, keywords = {volume status, peritoneal dialysis, multifrequency bioimpedance analysis}, isbn = {978-961-6956-52-9}, title = {Multifrequency bioimpedance analysis - a helping hand in precise and objective volume status control in peritoneal dialysis patients}, keyword = {volume status, peritoneal dialysis, multifrequency bioimpedance analysis}, publisherplace = {Portoro\v{z}, Slovenija} }




Contrast
Increase Font
Decrease Font
Dyslexic Font