Pregled bibliografske jedinice broj: 850165
Flow Injection Spectrophotometric Determination of N-acetylcysteine Ethyl Ester Based on the Reduction of Copper(II)-bicinchoninic Acid Complex
Flow Injection Spectrophotometric Determination of N-acetylcysteine Ethyl Ester Based on the Reduction of Copper(II)-bicinchoninic Acid Complex // Bulletin of the Chemists and Technologists of Bosnia and Herzegovina / Korać, Fehim (ur.).
Sarajevo: Prirodno-matematički fakultet Sarajevo, 2016. str. 53-53 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 850165 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Flow Injection Spectrophotometric Determination of N-acetylcysteine Ethyl Ester Based on the Reduction of Copper(II)-bicinchoninic Acid Complex
Autori
Kukoč-Modun, Lea ; Tsikas, Dimitrios ; Kraljević, Tomislav ; Biočić, Maja ; Radić, Njegomir
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Bulletin of the Chemists and Technologists of Bosnia and Herzegovina
/ Korać, Fehim - Sarajevo : Prirodno-matematički fakultet Sarajevo, 2016, 53-53
Skup
2nd International Congress of Chemists and Chemical Engineers of Bosnia and Herzegovina
Mjesto i datum
Sarajevo, Bosna i Hercegovina, 21.10.2016. - 23.10.2016
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
N-Acetylcysteine ethyl ester; Bicinchoninic acid; Flow injection.
Sažetak
A flow injection method of analysis was developed for the determination of a lipophilic cell-permeable cysteine derivative N-Acetylcysteine ethyl ester (NACET). NACET compared to its congener N-acetylcysteine poseses enhanced pharmacokinetic features. Once administered NACET quickly enters the cells where it is transformed to NAC and cysteine. The proposed method is based on a reduction reaction of an apple green Cu(BCA)22+ complex to a purple Cu(BCA)2+-complex by NACET in a phosphate buffer solution. The absorbance of the generated Cu(BCA)2+ complex is measured at 562 nm. Recorded peak height was used as a quantitative variable in the flow injection procedure. The absorbance of the formed Cu(BCA)2+, was recorded as a function of time with a recording frequency of 5 s–1. The linearity of the proposed flow injection method was obtained over the range 2.0×10–6 mol L-1 – 1.0×10–4 mol L–1 NACET, where the limit of detection was 6.6×10–7 mol L-1. Relative standard deviation obtained by measuring ten replicates of 4×10–5 mol L–1 NACET was found to be 0.7 %. Analytical frequency was 72 analysis per hour.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Projekti:
011-0000000-3217 - Određivanje tiola primjenom potenciometrijskih senzora i spektroskopije (Radić, Njegomir, MZOS ) ( CroRIS)
Ustanove:
Kemijsko-tehnološki fakultet, Split