Pregled bibliografske jedinice broj: 8493
NPP Krško RELAP5/MOD2 Analysis of Scaled BETHSY 6.2TC Test
NPP Krško RELAP5/MOD2 Analysis of Scaled BETHSY 6.2TC Test // Nuclear Energy in Central Europe; Book of Abstracts / Mavko, Borut (ur.).
Bled, Slovenija: Nuclear Society of Slovenia, 1997. (predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 8493 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
NPP Krško RELAP5/MOD2 Analysis of Scaled BETHSY 6.2TC Test
Autori
Šegon, Velimir ; Bajs, Tomislav ; Debrecin, Nenad
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Nuclear Energy in Central Europe; Book of Abstracts
/ Mavko, Borut - : Nuclear Society of Slovenia, 1997
Skup
International Conference of Nuclear Society of Slovenia: 4th Regional Meeting - Nuclear Energy in Central Europe
Mjesto i datum
Bled, Slovenija, 07.09.1997. - 10.09.1997
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Nije recenziran
Ključne riječi
scaling; counterpart test; small break LOCA
Sažetak
The present document deals with the RELAP5/MOD2 analysis of the NPP Krško scaled small break LOCA counterpart
test 6.2TC performed in the BETHSY facility.
BETHSY is a PWR simulator (integral test facility) located in Grenoble, France. The reference nuclear power plant
is a three loops, 900 MWe (2775 MWth), Framatome PWR. The volume scaling factor is 1:100 (more precisely 1.032*10-2).
NPP Krško is a Westinghouse two loops, 632 MWe, plant located in Krško, Slovenia.
The counterpart test is essentially a small break LOCA originated by a rupture in the cold leg between the pump and the
reactor vessel. The break is "side oriented" in the pipe and has an area equivalent, roughly, to 6% of the area of the main
pipe. The sequence of interventions of the various systems is typical of the kind of transient in a plant.
The small break LOCA was calculated using the nodalization of the NPP Krško developed at the Faculty of Electrical
Engineering and Computing for the scaled and nominal boundary and initial conditions. The scaling factor was the ratio
of the NPP Krško volume to the BETHSY volume (57.514). The results of the scaled calculation were compared
with the experimental data and with the results of a previous calculation performed by using the nodalization of the BETHSY
facility. Sensitivity studies were carried out for the scaled and nominal calculations.
The obtained results prove that the nodalization of the NPP Krško, developed at the Faculty of Electrical Engineering and
Computing, can be used for analyzing small break LOCA experiments.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika